Mira PLATINUM Installation Manual page 13

Hide thumbs Also See for PLATINUM:
Table of Contents

Advertisement

Typical Suitable Installations:
1. Instantaneous Multipoint Water Heaters and Combination Boilers
&DXWLRQ 5LVN RI SURGXFW GDPDJH 'R QRW ¿W WKH 0LUD 'LJLWDO 0L[HU  3803('
VALVE with Instantaneous Multipoint Water Heaters or Combination Boilers.
warm
cold
hot
COLD
HOT
Only install the High Pressure Digital Mixer Valve with a multipoint gas water
heater or combination boiler of a fully modulating design (i.e. where the water
GUDZRII UDWH LQGLUHFWO\ FRQWUROV WKH JDV ÀRZ UDWH WR WKH EXUQHU 
An expansion vessel must EH ¿WWHG DQG UHJXODUO\ PDLQWDLQHG LI DQ\ IRUP RI
EDFNÀRZ SUHYHQWLRQ GHYLFH LV ¿WWHG HJ QRQUHWXUQ YDOYH RU 359 7KLV ZLOO HQVXUH
that excess expansion or pulse pressures do not damage the product or plumbing
V\VWHP 7KH H[SDQVLRQ YHVVHO PD\ DOUHDG\ EH ¿WWHG ZLWKLQ WKH ERLOHU FKHFN
with the manufacturer) and is in addition to the normally larger central heating
expansion vessel.
Digital Mixer
Valve
ISOLATE MAINS ELECTRICITY BEFORE
REMOVING COVER!
DIGITAL MIXER 2 WIRELESS
MIRA DM2 WIRELESS
HP/COMBI
1666.009
N85A
MANUFACTURED
POWER: 230 V AC
20 W
PROTECTION: IP24
MIN. SUPPLY PRESSURE: 50 kPa (0.5 bar)
MAX. WORKING PRESSURE: 500 kPa (5 bar)
MAX. STATIC PRESSURE: 1000 kPa (10 bar) (WRAS)
MAX. SUPPLY WATER TEMP: 65 °C
POSITION APPLIANCE
OR
CHELTENHAM
KOHLER MIRA LTD.
GL52 5EP
TEL: (+44) 0870 241 0888
www.mirashowers.com
HOT
COLD
F9001
Key to Symbols
Mira Platinum
Shower Fittings
13
Float Valve
Isolating Valve
Pressure Reducing
Valve
Tempering Valve
2YHUÀRZ ,QGLFDWRU
Mini Expansion Vessel

Hide quick links:

Advertisement

Table of Contents
loading