Type Plate; Product Registration Number - SCAN 1008-S Assembly And Instruction Manual

Table of Contents

Advertisement

TYPE PLATE

All Scan built-in stoves are fitted with a type plate that specifies the approval standards and the distance to flammable materi-
als.
The type plate is placed loose in the fireplace.
Type plate Scan 1008
Scan 1008
Insert appliance fired by solid fuel
Standard:
EN 13229
Minimum distance to heat insulation:
Side: 25 mm - Back: 25 mm - Front: 800 mm
Minimum insulation:
See assembly- and instructions manual
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
The appliance can be operated in a shared flue.
Country
Classification
Certificate/Standard
EUR
Intermittent
EN 13229
Klasse 2
Norway
15a B-VG
Austria
Germany Stufe 2
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg

PRODUCT REGISTRATION NUMBER

All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of
this manual; you will always need to quote it when contacting your dealer or Scan A/S.
The product registration number is placed loose in the fireplace.
Product registration number
8000000
8
DoP 90580601
0,06%
800 mg/Nm³
6 mg/Nm³
195°C
6 kW
84%
Wood
Intermittent
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
05-2018
Type plate Scan 1008-S
Scan 1008-S
Freestanding room heater fired by solid fuel
Standard:
EN 13240
Minimum distance to combustible materials
Side: 0 mm - Back: 0 mm - Front: 800 mm
Follow assembly- and instructions manual.
The appliance can be operated in a shared flue.
CO emission at 13% O2:
Dust at 13% O2:
Flue gas temperature:
Nominal heat output:
Efficiency:
Fuel type:
Operation type:
Reaction to fire:
Country
Classification
Certificate/Standard
EUR
Intermittent
EN13240:2001
NS 3058
Norway
15a B-VG
ELAB-2100-AUS
Austria
Schweiz
LRV 11
VKF
Germany
Stufe 2
1. BlmSchV
Follow assembly- and instructions manual.
Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlene Brennstoffe.
1000
Scan A/S DK 5492 Vissenbjerg
DoP 90580602
0,06%
800 mg/Nm³
6 mg/Nm³
195°C
6 kW
84%
Wood
Intermittent
A1
Approved by
Teknologisk Institut
Teknologisk Institut
Teknologisk Institut
05-2018