(2) I/O address offset input "A0" and Data input "80", press I/O Write button.
=>All port (A/B/C) output of 82C55 will make Mode 0.
(3) I/O address offset input "A4" and Data input "FF", press I/O Write button.
=>"A" port of 82C55 record a "FF".
(4) It confirms whether or not output exactly come out as refer to specification Oscilloscope and JP1
connector.
(5) I/O address offset input "A4" Data input "0". After press I/O Write button, check the output od
Oscilloscope. It record "FF" of 82C55 A port.
(6) In the above test (3) ~ (4), you perform it to a port B/C.

4.4 Counter

(1) I/O address offset input "8" and Data input "1", press I/O Write button.
=> It is enable Counter 0 action.
(2) I/O address offset input "4" and Data input "3", press I/O Write button.
=> Target setup counter records "3".
(3) The counter 0 input (Pin #11) of connector P1 apply High Active pulse at once. After that, I/O
address offset input "0" and press I/O Read button. It confirms that current count make "1".
(4) It apply count pulse two times more. It confirm count over occurrence as reading a STATUS
register counter 0 and current counter value is "3".
(5) There is 3 Counter at PCI-EK01, remaining two counters shall test as above.

4.5 Timer

(1) I/O address offset input "34" and Data input "4", press I/O Write button.
=> It loads a Timer 0 setup value to a register.
(2) I/O address offset input "38" and Data input "5", press I/O Write button.
=> It turns over output in case of time-out at Auto-reload mode to frequency 0. At this time 5MHz
works if it try to confirm frequency. If it shows to formula
Frequency = 25M / (TMR_SET + 1)
A TMR_SET value shall over minimum 1.
(3) As result timer, it confirms that #22 (Timer 0) of P1 connector connect to Oscilloscope because
output works at pin #22.
(4) I/O address offset input "38" and Data input "d", press I/O Write button.
=> It prints out 20nSEC pulse in case of time-out at Auto-reload mode to frequency 0. At this time
10MHz works if it try to confirm frequency. If it shows to formula
Frequency = 50M / (TMR_SET + 1)
A TMR_SET value shall over minimum 1.
(5) There is 3 Timer at PCI-EK01, remaining two timers shall test as above.
30-
-
PCI-EK01 Users Manual (Rev 1.0)