17. Memory switch list

Display No.
SW
ON
Parameter setting change enabled (Parameter setting mode can be entered)
01
OFF
Parameter setting change disabled (Parameter setting mode cannot be entered)
ON
No interlock during thread trimming
02
OFF
No interlock during thread trimming (Invalid)
ON
Momentary drop or failure of power supply check valid
03
OFF
Momentary drop or failure of power supply check (lnvalid)
ON
SBT speed and EBT speed (No relation with high speed setting)
04
OFF
SBT speed and EBT speed (No more than of high speed setting)
ON
(Not used)
05
OFF
*Normally OFF
ON
No penetration force UP operation
06
OFF
Penetration force UP operation
ON
(Not used)
07
OFF
* Normally OFF
ON
(Not used)
08
OFF
* Normally OFF
Thread trimming validity setting enabled (F-operation panel is connected)
ON
* [
1 1
Thread trimming validity setting disabled (Treadle repression always includes thread
OFF
trimming)
Presser lifter rise after thread trimming when the treadle is neutral
(In the case of SW1-1 ON)
ON
Presser lifter descent after thread trimming when the treadle is neutral
(In the case of SW1-1 OFF)
1 2
Presser lifter descent after thread trimming when the treadle is neutral
(In the case of SW1-1 ON)
OFF
Presser lifter rise after thread trimming when the treadle is neutral
(In the case of SW1-1 OFF)
ON
Presser lifter rise after neutral stop when the treadle is neutral stop.
1 3
OFF
Presser lifter descent after neutral stop when the treadle is neutral stop.
ON
(Not used)
1 4
OFF
* Normally OFF
ON
Normally is deceleration
1 5
OFF
Quick stop is deceleration
ON
No over time [o t] function
1 6
OFF
Over time [o t] function (By a continuous 3 minutes stop)
[ ] OFF, Actuator switch = Half stitch correction switch
ON
[ ] ON, Actuator switch = 1 stitch correction switch
1 7
[ ] OFF, Actuator switch = Normally switch
OFF
[ ] ON, Actuator switch = 1 stitch correction switch
[ ] OFF, Actuator switch = Reverse stitch correction switch
ON
[ ] ON, Actuator switch = 1 stitch correction switch
1 8
[ ] OFF, Actuator switch = Normally switch
OFF
[ ] ON, Actuator switch = 1 stitch correction switch
42
] ON enabled, [
] OFF not enabled
MD-602, 612
* The shaded fields indicate the default values.