11. Changing the function settings
The function settings can be changed by changing the memory switch settings.
The operation timing, etc., can be changed by changing the parameter settings.
(Note) Operation panel F-40 or F-100 is required.
11.1 Example for changing the memory switch setting
11.1.1 When sewing thick materials, the needle may contact the material after thread trimming making it difficult to
remove the stitched product. Thus, the setting is changed so lift the needle with reverse run after trimming the thread. (Set
memory switch [ 61 ] to ON.)
1) Turn on the power switch, and erase the [ABCD] display. (When using F-100, set to pattern 1).
2) While pressing the [
3) Press the [
] key. The first display will be [1 1 - o ] (OFF) or [1 1 - @ ] (ON).
4) Set the memory switch No. to [ 61 ] using the [A, B+/–] keys. (The default setting is [ 61 - o ] (OFF).)
5) Press the [D+] key, and turn memory switch [ 61 ] ON. ([ 61 - @ ] (ON))
6) Using the [A+/–] key, set the [AB] display to [ E n ], and then press the [
7) Using the [B+] key, set the [AB] display to [ E n ], and then press the [
setting will be completed.
11.1.2 If you would like better matching for backtacking, this momentarily pauses feed at the corners so that the backtack
seams match. (Set memory switch [ 6 8 ] is turned ON.)
1) Turn on the power switch, and erase the [ABCD] display. (When using F-100, set to pattern 1).
2) While pressing the [
] key. The first display will be [1 1 - o ] (OFF) or [1 1 - @ ] (ON).
3) Press the [
4) Set the memory switch No. to [ 6 8 ] using the [A, B+/–] keys. (The default setting is [ 6 8 - o ] (OFF).)
5) Press the [D+] key, and turn memory switch [ 6 8 ] ON. ([ 6 8 - @ ] (ON))
6) Using the [A+/–] key, set the [AB] display to [ E n ], and then press the [
7) Using the [B+] key, set the [AB] display to [ E n ], and then press the [
setting will be completed.
11.2 Example for changing the parameter settings
11.2.1 If flickering of the fluorescent light is annoying when starting the motor, delay the motor startup and reduce the
power voltage fluctuation to reduce the fluorescent light flicker. (Change parameter [ M 6 ] from 10 to 30.)
1) Turn on the power switch, and erase the [ABCD] display. (When using F-100, set to pattern 1).
2) While pressing the [
3) Press the [B+] key. [ P A
If [ P A - - ] appears at the [AB] display, press the [B+] key twice, and return to the [ d S ] display. Then set the memory
switch [01] ON.
4) If [ P A ] is displayed at the [AB] display, press the [
5) Repeatedly press the [B-] key, and set the [AB] display to [ M 6 ]. ([ M 6 1 0 ] (default setting)]
6) Using the [CD+/–] key, set the parameter value to 30. ( [ M 6 3 0 ])
7) Press the [B+] key several times, set the [AB] display to [ E n ], and then press the [
to [ P A ]. ([ P A
])
8) Using the [B+] key, set the [AB] display to [ E n ], and then press the [
setting will be completed.
26
] key. [ d S ] will appear at the [AB] display.
] key, press the [
] key, press the [
] key. [ d S ] will appear at the [AB] display.
] key, press the [
] key. [ d S ] will appear at the [AB] display.
] will appear at the [AB] display.
] key. [ d S ] will reappear.
] key. The [ABCD] display will disappear, and the
] key. [ d S ] will reappear.
] key. The [ABCD] display will disappear, and the
] key. The first display will be [ t 0 0 2 ]. (Default setting value.)
] key. The [ABCD] display will disappear, and the
MD-602, 612
] key. The [AB] display will return