10.4 Setting the control box speed setting for the head

Change the speed setting for the following head settings highlighted in gray.
(1) Single needle
Head
B737/B201/B755
B791
B774
B722
B724
B748
B798/728
B722A
B778A
B781
B852/853/854
B883
Overlock
(2) Twin needle
Head
B842
B872
B845/875
B847
B848
B837
B877
B878
P73/P81
C51
10.4.1 Setting procedure
q Turn on the power switch and clear the [ABCD] display.
w Press the [
] key and the [
e Press the [
] key and the [
r Press the [
] key to change the type of speed displayed.
t Press the B [
] key until the speed to be changed appears.
y Press the [
] key to display the current speed setting.
u Set the speed to match the machine head. Use the [
i Press the [
] key to return to the speed display.
o Press the B [
] key until [ En ] is displayed.
!0 When [ En ] appears, press the [
!1 Repeat steps o and !0 until the display disappears to end the procedure.
Note:
• If you would like to set the maximum sewing speed and the start backtacking speed to be lower than the speed
which has been set by DIP switch 1 or the speed set in speed setting mode [ S P ]
The speed can be changed easily using the sewing speed key on the operation panel.
• The automatic sewing speed can only be set to be lower than the maximum sewing speed.
Inching
Thread
speed
trimming
[Lo]
speed [tr]
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
215
185
250
170
215
215
Inching
Thread
speed
trimming
[Lo]
speed [tr]
250
185
250
185
250
185
250
185
250
185
250
185
250
185
250
185
250
185
250
185
] key at the same time. [ d 5 ] appears in the display.
] key at the same time. [ S P ] appears in the display.
] key.
Slow
Start
speed
backtacking
[SL]
speed [Li]
215
1800
215
1800
215
1800
215
1800
500
1600
215
1200
215
1000
215
1800
215
1800
215
1800
215
1200
250
250
215
1800
Slow
Start
speed
backtacking
[SL]
speed [Li]
250
1000
250
1000
250
1000
250
1000
250
1000
250
1000
250
800
250
800
250
1000
250
1000
] and [
] keys to set the speed.
MD-602, 612
End
Improved
backtacking
stopping
speed [Eb]
[Po]
1800
1700
1800
1700
1800
1700
1800
1700
1600
1700
1200
1700
1000
1700
1800
1700
1800
1700
1800
1700
1200
1700
250
500
1800
1500
End
Improved
backtacking
stopping
speed [Eb]
[Po]
1000
1500
1000
1500
1000
1500
1000
1500
1000
1500
1000
1500
800
1500
800
1500
1000
1500
1000
1500
25