RELAY OPERATION
Normal
Alarm Relay
Closed
1
For information on Trouble conditions, see the
TROUBLESHOOTING
NORMAL
Alarm Relay
Closed
Red LED
Off
*TROUBLE CONDITIONS:
1
Self-Test Failure conditions:
• PIR self-test failure: The sensor is disabled.
• Temperature compensation failure: The temperature compensation is
disabled.
Depending on the Trouble condition, take the following corrective actions:
• Verify the power supply is sufficient (at least 9V at the sensor).
• Cycle power to the sensor.
•
Walk test
the sensor.
If the Trouble condition does not clear, replace the sensor.
SPECIFICATIONS
Range: 16 m x 22 m
Power: 9.0 - 15 VDC; 7 mA typical, 11 mA maximum, 12 VDC;
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Alarm Relay: Energized Form A; 30 mA, 25 VDC, 22 Ohms resistance
maximum. Alarm Relay Duration: 3 seconds
Trouble Relay: Energized Form B; (NC) 30 mA, 25 VDC; 22 Ohms
resistance maximum
Tampers: Cover; (NC with cover installed) Form A;
30 mA, 25 VDC; Magnetic field
RFI Immunity: 15 V/m, 80 MHz – 2.7 GHz
PIR White Light Immunity: 10,000 Lux typical
Fluorescent light filter: 50 Hz / 60 Hz.
Operating Temperature: -10° to 55° C
Relative Humidity: 5 to 95%; non-condensing
Temperature Compensation: Advanced Dual Slope
Dimensions: 9.8 cm H x 5.7 cm W x 4.35 cm D
Weight: 80 g (net weight)
2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.
www.honeywell.com/security
SENSOR STATUS
1
Intrusion
Trouble
Open
Open
Troubleshooting
section.
TROUBLE*
1
Self-Test Failure
Open
Flashing
Zones
A
B
C
D
ACCESSORIES
SMB-10
Swivel Mount Bracket
(P/N 0-000-110-01)
SMB-10C
Swivel Mount Ceiling Bracket
(P/N 0-000-111-01)
SMB-10T
Swivel Mount Bracket w/Tamper
(P/N 0-000-155-01)
Note : The accessories are not covered by certifications.
APPROVAL LISTINGS
EN50131-2-2:2008, Security Grade 2,
Environmental Class II.
Suitable for connection to an EN 60950 Class II
Limited Power Source.
Note: In EN 50131-2-2 compliant installations, mount the sensor at 2.3m,
enable look down and lock the sensor housing with the cover lock (see
"[EN]" where noted in Steps 1-4).
IMPORTANT: The sensor should be tested at least once each year.
NF&A2P 2 boucliers (référentiel NF324-H58)
et conforme aux normes EN50131-2-2 et
RTC50131-2-2; IP30 IK04
N° de certificat: 2821420019
Organisme de certification:
CNPP Cert. : www.cnpp.com et
AFNOR Cert.: www.marque-nf.com
Honeywell Security Group - BP1219
1198 avenue du docteur Maurice Donat
Sophia Antipolis
06254 Mougins Cedex
TEL: +33.4.92.94.29.50
FAX: +33.4.92.94.29.60
For any additional information, please refer to our Website:
http://www.honeywell.com/security/emea/hscdownload
Or contact:
Honeywell Security Group
Newhouse Industrial Estate
Motherwell
Lanarkshire ML1 5SB
United Kingdom
Please contact your local authorised Honeywell representative for
product warranty information.
2
Look-down
18
Lower
20
Intermediate
54
Long
PD6662:2010
INCERT B-893-0015
LARMKLASS 2
Corrente norminale: 12 =
Corrente massima
assorbita: 11 mA
Tel: +44(0)1698 738200
Email: UK64Sales@Honeywell.com
P/N 800-16904 Rev A