Operation; Troubleshooting And Maintenance - Honeywell R7184A Series Quick Start Manual

5 interrupted electronic oil primary, enviracom enabled
Hide thumbs Also See for R7184A Series:
Table of Contents

Advertisement

R7184A,B,P,U SERIES 5 INTERRUPTED ELECTRONIC OIL PRIMARY, ENVIRACOM™ ENABLED
C7089B
OUTDOOR
TEMPERATURE
SENSOR
W8635A
L2
L1
(HOT)
SYSTEM
TRANSFORMER
5
R7184
T
T
3
2
1
BURNER
MOTOR
IGNITOR
TO
CAD
REMOTE
CELL
ALARM
ALARM
2
CIRCUIT
LEGEND:
SCREW TERMINAL
SOLDERLESSWIRE CONNECTOR
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
2
OPTIONAL FEATURE ON SELECT MODELS.
REFER TO DEVICE LABEL FOR WIRE COLOR CODE.
3
VALVE IS OPTIONAL ON SPECIFIC MODELS.
4
FACTORY INSTALLER JUMPERS.
5
6
ENVIRACOM™ TERMINAL 3 IS ALSO THE FIRST THERMOSTAT TERMINAL.
Fig. 7. Typical wiring diagram for EnviraCOM™
enabled thermostat and R7184 for an
oil-fired forced-air system.
IMPORTANT
System as shown in Fig. 7 is phase/polarity
sensitive. Make sure all input power is in the
same phase.
69-1459—4
T8635L
2
OT
OT
1
3
1
2
3
G
C
W1
R
W2
Y1
R H
R C
Y2
LIMIT
LIMIT
L1
L2
3
VALVE
BURNER
MOTOR
3
IGNITOR
CAD
CELL
JUNCTION
BOX
1/4 IN. QUICK CONNECT TERMINAL
JUMPER
ENVIRACOM™
TERMINAL
5
TO
FAN
REMOTE
RELAY
ALARM
2
CIRCUIT
COOL 1
RELAY
COOL 2
RELAY
LEGEND:
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
2
OPTIONAL FEATURE ON SELECT MODELS.
1
3
REFER TO DEVICE LABEL FOR WIRE COLOR CODE.
L1
HOT
4
VALVE MAY BE ADDED AS SHOWN ON PRIMARIES THAT DO NOT
L2
HAVE A VALVE LOAD.
5
ENVIRACOM™ TERMINAL 3 IS ALSO THE FIRST
THERMOSTAT TERMINAL.
Fig. 8. Typical wiring diagram for line voltage,
EnviraCOM™ enabled, Aquastat® and R7184 for an
oil thermostat and R7184A,B for an oil burner

OPERATION

The R7184 is a microprocessor-based control. The
indicator light provides diagnostic information for lockout,
recycling and patented cad cell status. There is a manual
reset button to exit the lockout mode and enter the idle
mode. (See Fig. 2.) Operation is shown in Table 4.
TROUBLESHOOTING AND
MAINTENANCE
IMPORTANT
M19978A
Due to the potential hazard of line voltage, only
a trained, experienced service technician
should preform the troubleshooting procedures.
This control contains no field-serviceable parts.
Do not attempt to take it apart. Replace entire
control if operation is not as described.
To completely troubleshoot an oil burner installation,
check the burner and oil primary control for proper
operation and condition.
The indicator light on the oil primary control provides
lockout, recycle and cad cell indications as follows:
6
LINE VOLTAGE
R7184
T
THERMOSTAT
L1
OR AQUASTAT®
CONTROL
T
3
3
L2
2
1
BURNER
MOTOR
3
IGNITOR
CAD
CAD
ALARM
CELL
CELL
JUNCTION
BOX
SCREW TERMINAL
1/4 IN. QUICK CONNECT TERMINAL
SOLDERLESSWIRE CONNECTOR
system.
1
L1
LIMIT
HOT
L2
VALVE
4
BURNER
MOTOR
IGNITOR
M17748B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R7184b seriesR7184p seriesR7184u series

Table of Contents