Download Print this page
Honeywell IntelliSense IS2535TC Installation Instructions
Honeywell IntelliSense IS2535TC Installation Instructions

Honeywell IntelliSense IS2535TC Installation Instructions

Passive infrared motion sensor

Advertisement

Quick Links

Select the mounting location.
Aim away from:
Mounting Location Guidelines
• 2.3 m - 2.7 m (7.5' - 9')* mounting height.
• Avoid direct or reflected sunlight.
• Aim sensor away from windows or heating/cooling devices.
• Sensor must have a clear line-of-sight to protected area.
• If using in a pet application, remove the High Security lens
and replace with the Pet Immune Lens (see Step 5).
*See Special Instructions for pet applications.
Select the appropriate lens* for the installation. If necessary, mask segments as required. (Refer to the
Masking the Lens section.)
*Lens options: Pet Immune or High Security/Non-Pet Immune [factory default] lens.
To change the lens:
• Pull up on the bug guard latches with two fingers and remove the bug
guard with the other hand.
• Pull outward on the lens flange (single-slotted) of the existing lens and
remove the lens.
• Align the double-slotted lens flange to the bug guard, SMOOTH side
facing outward, and snap the single-slotted lens flange in place.
• Place the bug guard into the look-down window and press it into place.
Separate the sensor housings and remove the printed cir-
cuit board (PCB).
• Use a small screwdriver to remove the cover screw (if
installed), then push in the housing latch at the bottom of the
sensor, and gently pull apart the housings.
• Push outward on the PCB latch and lift the PCB out of the
housing.
The PCB alignment
guide should
always point down,
as shown.
SWITCH
1 (PC)
2 (SENS)
3 (LED)
4 (POL)
Polarity
Test* Input
Arm Input
(Notes: Default switch settings are shown in grey.
See the Specifications section for more information on the
Mount the unit.
Wire
Knockouts
Corner
Mount
Strain Relief Options
Knockouts
Wall Mount
Knockouts
#6
pan-head
screws
Tamper Knockout
• Slide the wire through the wire knockouts in the
back housing, attach the wire with a wire tie,
and cut off the excess wire tie.
• Mount the back housing flat against a wall or in
a corner using #6 screws supplied. [Notes: If
using the wall tamper, refer to the Tamper
Switches section. If using a mounting bracket
see the Accessories section, and follow the
installation instructions supplied with the
bracket.]
• Replace the PCB.
• Seal any openings with RTV compound.
Set the DIP switches.
Configure the sensitivity and walk-test the sensor.
Set the sensitivity appropriate for the application (see options below), replace the front cover, and apply
Install the look-down mask (black ring
supplied), if desired, to reduce the look-
power to the sensor. Begin walk-test after the LED stops flashing (see the LED Operation section). Walk
End of Line
down sensitivity for pet applications.
(EOL) Screws
through the detection zones, observing the sensor's LED whenever motion is detected. The red LED shows
actual alarm relay operation.
The absolute range of all PIR units is subject to variation because of different types of clothing, backgrounds, and
ambient temperature. For this reason, ensure that the most likely intruder routes are well within the PIR's detection
Terminal
zones and that walk-testing is carried out along those routes.
Block
LED
DIP
Switch
OFF
ON
Pulse Count 2
Pulse Count 1
Low Sensitivity
High Sensitivity
LED Disabled
LED Enabled
Active High
Active Low
(L) = Test*; (H) = Normal
(H) = Test*; (L) = Normal
(L) = Arm; (H) = Disarm
(H) = Arm; (L) = Disarm
Test/Arm inputs. *Test = Remote LED Enable.)
Wire the sensor. Connect wires to terminal as shown using wire size 0.8
- 1.5 mm (22-16 AWG). Observe the proper polarity.
Test/Arm
TAMPER
ALARM
POWER
Test/Arm
0 VDC - V
,
30 mA,
30 mA,
21 mA, 12 VDC*,
0 VDC - V
,
supply
supply
1.8 mA max
24 VDC
24 VDC
25 mA max
1.8 mA max
Normally Closed Loop, No EOL Resistor
Normally Open Loop, No EOL Resistor
Test/Arm
TAMPER
ALARM
POWER
Test/Arm
0 VDC - V
,
30 mA,
30 mA,
21 mA, 12 VDC*,
0 VDC - V
,
supply
supply
1.8 mA max
24 VDC
24 VDC
25 mA max
1.8 mA max
Normally Closed Loop, w/ EOL Resistors
Normally Open Loop, w/ EOL Resistors
Note: EOL = Single End-of-Line supervised resistor.
*For UL voltage, see Specifications Section.
Note: For High Security applications, use the High Security Lens, disable
the LED (S3=OFF), and set the sensitivity to High (S1 and S2=ON).
TAMPER
ALARM
POWER
30 mA,
30 mA,
21 mA, 12 VDC*,
24 VDC
24 VDC
25 mA max
TAMPER
ALARM
POWER
30 mA,
30 mA,
21 mA, 12 VDC*,
24 VDC
24 VDC
25 mA max

Advertisement

loading

Summary of Contents for Honeywell IntelliSense IS2535TC

  • Page 1 ❶ ❷ ❸ ❹ Select the mounting location. Separate the sensor housings and remove the printed cir- Mount the unit. Wire the sensor. Connect wires to terminal as shown using wire size 0.8 cuit board (PCB). - 1.5 mm (22-16 AWG). Observe the proper polarity. Wire Knockouts Corner...
  • Page 2 MASKING THE LENS may cause undesired operation. The user is cautioned that changes or modifications not expressly approved by Honeywell could void the user’s authority to operate To Disable the alarm LED, turn switch S3 OFF. The LED will If the installation requires some segments of the detection pattern to be blocked off, this equipment.