Download Print this page

Program The Sensor; Troubleshooting; Specifications; Accessories - Honeywell V-Plex Series Installation Instructions Manual

Motion sensor with anti-mask

Advertisement

PROGRAM THE SENSOR

This sensor is a serial number device. Refer to the control
panel's manual for instructions on registering devices and
programming.
®
For all V-Plex
panels, program the sensor Zone Type as INT
FOLLOWER 04 and the INPUT TYPE as "06" (for SL - Serial
Polling Device).
®
If using a Smart V-Plex
panel, program the sensor to
Standard mode [press "0" (No)] or SMART CONTACT mode
[press "1" (Yes)].
Standard Mode: The sensor includes a selectable High Traffic
Inhibit (HTI) feature. This feature reduces bus traffic with a
randomized delay (from 5 – 15 seconds) between alarm
signals after an alarm and restoral signal is sent. In
applications where this delay is not necessary, set DIP Switch
1 to OFF.
IMPORTANT: If using the Anti-Mask feature, the sensor MUST
be programmed to
Standard Mode.
Smart Contact Mode: In the Smart Contact mode, the sensor
automatically reduces bus traffic by not sending alarm signals
when disarmed.
ALL modes: Tamper, self-test failures and anti-mask
are sent without delays.
1
Anti-mask signals are only sent when Anti-mask is enabled
(DIP switch 2 ON), except during Microwave Walk Test mode.
See step 6.
LED OPERATION
The LED can be enabled in several ways:
− After power up mode the LED is enabled for 10 minutes (DIP
switch 3 ON or OFF).
− Remove and replace the front cover to enable the LED for
10 minutes (DIP switch 3 ON or OFF).
− Set DIP switch 3 ON (LED Enable); LED remains enabled
until disabled (switch 3 OFF). [Exception: When
programmed to Smart Contact mode and the system is
armed, the LED is always disabled.]
− Remote LED Enable. [If using a Smart V-Plex
Remote LED Enable feature may be available, which allows
remote enabling of the LED if DIP switch 3 is OFF. (Refer to
the Burglary Walk-Test section in the control panel's
manual.) Using this method, the LED remains enabled while
the panel is in the burglary walk test mode.]
MASK CONDITION
Normal Anti-Mask Condition
The sensor uses Active Infrared (AIR) technology to detect
masking. The sensor signals a mask condition when a variety
of materials and reflective objects are placed within 2 inches
(50mm) in front of the sensor. To avoid false mask alarms,
follow the mounting guidelines shown in Step 1.
Clearing an Anti-Mask Condition
When most masking materials or objects are removed, the
anti-mask condition will be cleared after several seconds.
When the cause of the anti-mask condition is any type of spray
or paint coating applied to the window, the window must be
replaced before the anti-mask condition can be cleared. After
replacing the window, perform a walk test on the sensor.

TROUBLESHOOTING

*TROUBLE CONDITIONS:
1
Mask condition: Sensor IR window is blocked or masked.
2
Self-Test Failure conditions:
• Microwave supervision failure: The sensor is operating in PIR mode only.
• PIR self-test failure: The sensor is disabled.
• Temperature compensation failure: The temperature compensation is disabled.
Depending on the Trouble condition, take the following corrective actions:
• Verify the sensor is not blocked or masked.
• Cycle power to the sensor.
• Walk test the sensor.
If the Trouble condition does not clear, replace the sensor.

SPECIFICATIONS

Range: 53' x 72' / 16 m x 22 m
Wall Mounting Height: 6'9" - 8'9" (2.1 m - 2.7 m); Optimal 7'6" (2.3 m)
Power: 9.0-13V PK – PK at polling loop terminals; (UL: 9.5-15VDC);
4 mA maximum.
Tampers: Cover & Wall
Microwave Frequencies: 10.525 GHz
RFI Immunity: 20V/m 10-1000MHz, 15V/m 1000-2700MHz
1
signals
PIR White Light Immunity: 6,500 Lux typical
Fluorescent light filter: 50 Hz / 60 Hz.
Operating Temperature: 14° to 131° F / -10° to 55° C
Relative Humidity: 5 to 93% (UL tested at 93%); non-condensing
Temperature Compensation: Advanced Dual Slope
Dimensions: 4.57" H x 2.76" W x 1.69" D /
11.6 cm H x 7.0 cm W x 4.3 cm D
Weight: 5 oz / 142 g (net weight)

ACCESSORIES

SMB-10*
(P/N 0-000-110-01)
SMB-10C*
(P/N 0-000-111-01)
SMB-10T*
®
panel, a
(P/N 0-000-155-01)
Cable* (P/N 1103)
Cable* (P/N 1104)
Cable* (P/N 1106)
Cable* (P/N 1107)
* Not evaluated by UL.
- 4 -
NORMAL
Red LED
Off
Yellow LED
Off
Flashing
Swivel Mount Bracket
Swivel Mount Ceiling Bracket
Swivel Mount Bracket w/Tamper
General purpose, Solid 22 AWG,
4 conductor
General purpose, Stranded 22
AWG, 4 conductor
General purpose, Solid 22 AWG,
6 conductor
General purpose, Stranded 22
AWG, 6 conductor
TROUBLE*
1
Mask
Self-Test Failure
Off
Flashing
Off
2

Advertisement

loading

This manual is also suitable for:

Dt805a-snV-plex dual tec