Electrical and Output Specifications for CBS-1151 XV+ Single 1½ Gallon-6 Liter Coffee Brewers
Domestic USA and Canada
Configuration
Heater
Codes
Configuration
E115151
2 X 3.0 kW
Domestic & International Versions
E115190
1 X 4.0 kW
E115191
1 X 5.0 kW
E115192
2 X 3.0 kW
E115193
2 X 2.3 kW
Export CBS-1151XV+
E115180
1 X 5.0 kW
CE With Internal EMI Filter.
(CE) E115162
2 X 2.3 kW
(CE) E115161
2 X 3.0 kW
.
Electrical and Output Specifications-for CBS-1152 XV+ Twin 1½ Gallon-6 Liter Coffee Brewers
USA and Canada
Configuration
Heater
Codes
Configuration
E115251
2 X 3.0 kW
Selectable
3 X 3.0 kW
Sold as1 phase
E115252
2 X 5.0 kW
Selectable
3 X 5.0 kW
Sold as1 phase
Domestic & International Versions
E115292
2 X 3.0 kW
E115294
2 X 5.0 kW
E115296
3 X 4.0 kW
E115290
3 X 3.0 kW
E115291
3 X 5.0 kW
Export
E115280
3 X 3.0 kW
CE With Internal EMI Filter.
(CE) E115261
3 X 3.0 kW
(CE) E115262
3 X 5.0 kW
Go to fetco.com for the latest versions of all information
CBS-1151 XV+ Standard-Voltage With cUL/UL & NSF-4 Certification
Voltage
Phase
Wires
208-240
1
2+G
CBS-1151 XV+ With cUL/UL & NSF-4 Certification
200-240
1
2+G
200-240
1
2+G
200-240
1
2+G
200-240
1
2+G
With cUL/UL & NSF-4 Certification
200-240
1
2+G
CBS-1151 XV+ With CE & NSF-4 certification. Not cUL or UL Listed
2L,N,PE Terminal Block
230/400
2
2L,N,PE Terminal Block
230/400
2
CBS-1152 XV+ Field Selectable Electrical With cUL/UL & NSF-4 Certification
Voltage
Phase
Wires
200-240
1
2+G
200-240
3
3+G
200-240
1
2+G
200-240
3
3+G
CBS-1152 XV+ Standard-Voltage With cUL/UL & NSF-4 Certification
200-240
1
2+G
200-240
1
2+G
240/415
3
4+G
220/380
or
3
4+G
240/415
220/380
or
3
4+G
240/415
CBS-1152 XV+ With cUL/UL & NSF-4 Certification
200
3
3+G
CBS-1152 XV+ With CE & NSF-4 Certification. Not cUL or UL Listed
230/400
3
3L,N,PE
230/400
3
3L,N,PE
Electrical
KW
Connection
Terminal Block 4.6-6.1
Terminal Block
4.1
Terminal Block
5.1
Terminal Block
6.1
Terminal Block
4.7-6.1
Terminal Block
3.6
5.6
6.1
Electrical
KW
Connection
Terminal Block
4.6-6.1
Terminal Block
6.9-9.1
Terminal Block
7.6-10.1
Terminal Block 11.4-15.1 32.0-36.9 38.3 gal/145
Terminal Block
4.6-6.1
Terminal Block
7.6-10.1
Terminal Block
12.2
Terminal Block
9.1
Terminal Block
15.1
Terminal Block
6.5
Terminal Block
8.6
Terminal Block
14.1
Page 3
Maximum
Brew-
Amp Draw
Volume/Hour
22.4-25.8
15.3 gal/58 liters
14.2-17.1
9.3 gal/35 liters
17.7-21.3
12.7 gal/48 liters
21.3-25.5
15.3 gal/58 liters
22.1-25.5
14.0 gal/53 liters
17.7
11.6 gal/44liters
12.4
14.0 gal/53 liters
21.3-25.5
15.3 gal/58 liters
Maximum
Brew-
Amp Draw
Volume/Hour
22.4-25.8
15.3 gal/58 liters
19.5-22.5
22.5 gal/85 liters
36.9-42.5
25.3 gal/97 liters
22.4-25.8
15.3 gal/58 liters
36.9-42.5
25.3 gal/97 liters
15.7-17.1
29.5 gal/112liters
11.8-12.9
22.5 gal/85 liters
19.5-21.4 38.3 gal/145
18.6
17 gal/64 liters
12.4
22.5 gal/85 liters
20.4
38.3 gal/145 liters
P167 March 2018
liters
liters

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-1151-xv+Cbs-1152-xv+