Simulations - Sharp AL-1600 Service Manual

Al series
Hide thumbs Also See for AL-1600:
Table of Contents

Advertisement

[8] SIMULATION
1. Entering the simulation mode
Perform the following procedure to enter the simulation mode.
Clear key → Interruption key → Shift key → Interruption key → Start
key → Sub code → Start key
2. Cancelling the simulation mode
When the all clear key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and
the screen returns to the sub code entering display.
3. List of simulations
Main
Sub
code
code
1
1
Mirror unit operation check
2
Optical system sensor operation check
2
1
SPF aging
2
SPF sensor operation check
3
SPF motor forward rotation operation check
4
SPF motor reverse rotation operation check
8
SPF paper feed solenoid operation check
9
SPF reverse solenoid operation check
10
SPF paper exit gate solenoid operation check
11
SPF PS release solenoid operation check
3
2
Shifter job separator sensor operation check
3
Shifter operation check
4
Job separator operation check
10
Job separator home position check
5
1
Operation panel display check
2
Heater lamp lighting check, cooling fan motor
operation check
3
Copy lamp lighting check
6
1
Paper feed solenoid operation check
10
Main cassette paper feed roller drive
7
1
Aging with JAM with warmup time display
2
Aging without JAM with warmup time display
4
Warmup saving
6
Intermittent aging (with paper)
7
Intermittent aging (without paper)
8
Warmup time display
8
1
Developing bias voltage output check
2
Main charger voltage output check (Grid bias high
mode)
3
Main charger voltage output check (Grid bias low
mode)
6
Transfer charger voltage check
9
1
Duplex motor forward rotation operation check
2
Duplex motor reverse rotation operation check
4
Duplex motor rotation speed adjustment
5
Duplex motor switchback time adjustment
10
Toner motor operation check
14
Trouble (except for U2) cancel
16
U2 trouble cancel
17
PF trouble cancel
20
1
Maintenance counter clear
21
1
Maintenance cycle setting
2
Mini maintenance counter display
22
1
Maintenance counter display
2
Maintenance preset value display
Contents
Main
Sub
code
code
22
3
JAM memory display
4
Total JAM counter display
5
Total counter display
6
Developing counter display
7
Developing preset counter value display
8
SPF counter display
9
Paper feed counter display
12
Drum counter display
14
Flash ROM version display
15
Trouble memory display
16
Duplex print counter display
17
Copy counter display
18
Printer counter display
19
Electronic sort counter display
20
FAX print counter display
21
Scanner counter display
24
1
JAM memory, JAM counter clear
2
Trouble memory clear
4
SPF counter clear
5
Duplex counter clear
6
Paper feed counter clear
7
Drum counter clear
8
Copy counter clear
9
Printer counter clear
10
Electronic sort counter clear
11
FAX print counter clear
13
Scanner counter clear
25
1
Main motor operation check
10
Polygon motor operation check
26
1
Operation switch display
3
Auditor setting
5
Counter mode setting
6
Destination setting
22
Language setting
30
CE mark conformity control setting
30
1
Machine sensor operation check
41
2
OC document sensor adjustment
3
Document sensor light reception level display
42
1
Developer counter clear
43
1
Fusing temperature setting
46
1
Copy density level adjustment
2
FAX density level adjustment
48
1
Main scanning (front/rear) direction magnification
ratio adjustment(Copy/FAX/OC-SPF common)
2
OC mode sub scanning direction magnification
ratio adjustment in copying
5
SPF mode sub scanning direction magnification
ratio adjustment in copying
6
OC mode sub scanning direction magnification
ratio adjustment in FAX
7
SPF mode sub scanning direction magnification
ratio adjustment in FAX
50
1
Copy image position adjustment
10
Paper off center adjustment
13
OC mode document off center adjustment
16
SPF mode document off center adjustment
51
2
Resist amount adjustment
63
1
Shading data check
64
1
Self printing mode
69
1
Program download mode
8 – 1
AL-1610
Contents

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-1610

Table of Contents