Sharp AL-1600 Service Manual page 34

Al series
Hide thumbs Also See for AL-1600:
Table of Contents

Advertisement

AL-1610
Main
Sub
Contents
code
code
7
2
Aging without JAM with
warmup time display
4
Warmup saving
6
Intermittent aging (with
paper)
7
Intermittent aging (without
paper)
8
Warmup time display
8
1
Developing bias voltage
output check
2
Main charger voltage
output check (Grid bias
high mode)
3
Main charger voltage
output check (Grid bias
low mode)
6
Transfer charger voltage
check
9
1
Duplex motor forward
rotation operation check
2
Duplex motor reverse
rotation operation check
4
Duplex motor rotation
speed adjustment
5
Duplex motor switchback
time adjustment
10
Toner motor operation
check
14
Trouble (except for U2)
cancel
16
U2 trouble cancel
17
PF trouble cancel
Details of operation
Used to start warmup and count and display the warmup time every
second. After completion of warmup, count up is terminated and the
ready lamp is lighted. When the clear key is pressed and the copy
quantity is entered and the start key is pressed, copying is made to make
the set quantity of copies. At that time, the paper size does not matter.
Key operation
Copy quantity setting: Copy quantity key
Used to bring the machine to the ready state without warmup.
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter.
Key operation
Copy quantity setting: Copy quantity key
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter.
Key operation
Copy quantity setting: Copy quantity key
Used to count and display the warmup time from 0 at every second.
Used to output the developing bias for 30 sec. For the adjustment proce-
dure of the developing bias, refer to the previous descriptions.
Used to output the main charger grid bias voltage at the high mode for
30 sec. For the adjustment procedure of the main charger grid bias
voltage, refer to the previous descriptions.
Used to output the main charger grid bias voltage at the low mode for 30
sec. For the adjustment procedure of the main charger grid bias voltage,
refer to the previous descriptions.
Used to output the transfer charger voltage for 30 sec. For the adjust-
ment procedure of the transfer charger voltage, refer to the previous
descriptions.
Used to rotate the duplex motor forward for 30 sec.
Used to rotate the duplex motor reversely for 30 sec.
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor rotation speed set value is displayed.
When the set value is entered and the start key is pressed, the set value
is stored.
Key operation
Duplex motor rotation speed set value: Copy quantity key
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor switchback time set value is displayed.
When the set value is entered and the start key is pressed, the set value
is stored.
Key operation
Duplex motor switchback time set value: Copy quantity key
Used to operate the toner motor for 30 sec.
Note: If this simulation is executed with the toner hopper installed, toner
is automatically supplied to the developer. Be careful of overtoner.
Used to cancel troubles except for U2.
Used to cancel U2 trouble.
Used to cancel PF trouble.
8 – 4
Initial
Set range
value
1 ~ 99
1 ~ 99
1 ~ 99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Al-1610

Table of Contents