[8] SIMULATION, TROUBLE CODES
1. Contents of simulations
Main code Sub code
26
4
Main body duplex setting
(Operation/procedure)
1. When this simulation is executed, the currently set duplex code number is displayed.
2. ???????
Code number
43
1
Fusing temperature setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number
4
Multi copy fusing temperature setting
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
Code number
5
Fusing temperature setting in duplex copying
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number corresponding to the duplex and press the START key. The setting is changed accordingly.
Code number
∗ The above shift temperature set by this simulation is added to the fusing temperature of single copy.
Duplex
0
Without Duplex
1
With Duplex
Set temperature (˚C)
0
175
1
180
2
185
3
190
4
195 (∗ Default)
5
200
Set temperature (˚C)
0
155
1
160
2
165
3
170 (∗ Default)
4
175
5
180
Shift temperature (˚C)
±0˚C
0
1
–8˚C
2
–6˚C
3
–4˚C
4
–2˚C
±0˚C
5
6
+2˚C
7
+4˚C
8
+6˚C
9
+8˚C
Content
8 – 1
AL-1550