VOYAGEUR Insert ACC
C. Negative Pressure
WARNING
Asphyxiation Risk.
Negative pressure can cause spillage
of combustion fumes, soot and carbon
monoxide.
Appliance needs to draft properly for
safety.
Negative pressure results from the imbalance of air
available for the appliance to operate properly. It can be
strongest in lower levels of the house.
Causes include:
Exhaust fans (kitchen, bath, etc.)
Range hoods
Combustion air requirements for furnaces, water
appliances and other combustion appliances
Clothes dryers
Location of return-air vents to furnace or air
conditioning
Imbalances of the HVAC air handling system
Upper level air leaks such as:
-
Recessed lighting
-
Attic hatch
-
Duct leaks
To minimize the effects of negative air pressure:
Install optional outside air kit with the intake facing
prevailing winds during the heating season
Ensure adequate outdoor air for all combustion
appliances and exhaust equipment
Ensure furnace and air conditioning return vents are
not located in the immediate vicinity of the appliance
Avoid installing the appliance near doors, walkways or
small isolated spaces
Recessed lighting should be a "sealed can" design
Attic hatches weather stripped or sealed
Attic mounted duct work and air handler joints and
seams taped or sealed
Basement installations should be avoided
6
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
Installation and use of any damaged appliance.
Modification of the appliance.
Installation other than as instructed by Hearth &
Home Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all
components.
Operating appliance without legs attached (if supplied
with appliance).
Do NOT Over fire - If appliance or chimney connector
glows, you are over firing.
Any such action that may cause a fire hazard.
D. Tools And Supplies Needed
Before beginning the installation be sure the following tools
and building supplies are available:
Reciprocating saw
Framing material
Pliers
High temp caulking material
Hammer
Gloves
Phillips screwdriver
Framing square
1/2-3/4 in. length, #6 or #8 self-drilling screws
E. Inspection of Appliance and Components
Remove appliance and components from packaging
and inspect for damage.
Report to your dealer any parts damaged in shipment.
Read all the instructions before starting the
installation. Follow these instructions carefully
during the installation to ensure maximum safety
and benefit.
Fire Risk.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
Report damaged parts to dealer.
7063-513I
WARNING
Flat blade screwdriver
Electric drill and bits
Plumb line
Safety glasses
Level
Tape measure
Misc. screws and nails
7/16 socket or wrench