15. Appendices
15.2. Thermal dissipation charts
Model - IPD 2400
Level
Load
Standby w. remote Power Off.
Power on, Idling
16 Ω / Ch.
8 Ω / Ch.
Pink Pseudo
Noise (1/8)
4 Ω / Ch.
2 Ω / Ch.
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified here
is what is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. as well as 120 V. The efficiency is similar, but not identical for the two scenarios. The efficiency for 100 V mains is
very similar to that of 120 V.
28
IPD SERIES Operation Manual rev 2.0.0
IPD 2400
Mains
Line
Rated power
voltage
current
VAC
IAC *2)
230
0.088
120
0.0981
100
0.11
230
0.229
120
0.383
100
0.44
230.0
1.1
300
x 2
120.0
1.7
100.0
1.8
230.0
1.9
600
x 2
120.0
3.0
100.0
3.8
230.0
3.3
1200
x 2
120.0
5.3
100.0
6.1
230.0
2.3
800
x 2
120.0
3.4
100.0
4.1
Watt *1)
In
Out
Dissipated
7.10
0
7
6.45
0
6
6.45
0
6
28.20
0
28
29.20
0
29
27.40
0
27
127
75
52
127
75
52
114
75
39
218
150
68
229
150
79
239
150
89
431
300
131
455
300
155
451
300
151
279
150
129
260
150
110
258
150
108
Thermal Dissipation
BTU/hr
kCal/hr
24
6
22
6
22
6
96
24
100
25
94
24
178
45
177
45
134
34
233
59
270
68
303
76
448
113
530
133
514
129
439
111
376
95
368
93