Thermal Dissipation Charts - Lab.gruppen IPD 1200 Operation Manual

Intelligent power drive, ipd series
Table of Contents

Advertisement

15.2. Thermal dissipation charts

Model - IPD 1200
Level
Load
Standby w. remote Power Off.
Power on, Idling
16 Ω / Ch.
8 Ω / Ch.
Pink Pseudo
Noise (1/8)
4 Ω / Ch.
2 Ω / Ch.
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct. Instead, measured and specified here
is what is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. as well as 120 V. The efficiency is similar, but not identical for the two scenarios. The efficiency for 100 V mains is
very similar to that of 120 V.
IPD 1200
Mains
Line
Rated power
voltage
current
VAC
IAC *2)
230
0.07
120
0.01
100
0.1
230
0.21
120
0.36
100
0.39
230.0
0.5
150
x 2
120.0
1.0
100.0
1.1
230.0
0.9
300
x 2
120.0
1.6
100.0
1.8
230.0
1.8
600
x 2
120.0
3.0
100.0
3.4
230.0
1.7
500
x 2
120.0
2.8
100.0
3.4
Watt *1)
In
Out
Dissipated
6.50
0
7
6.05
0
6
6.05
0
6
25.80
0
26
26.50
0
27
24.90
0
25
68
38
30
71
38
34
71
38
34
119
75
44
122
75
47
122
75
47
226
150
76
234
150
84
229
150
79
217
125
92
211
125
86
222
125
97
IPD SERIES Operation Manual rev 2.0.0
15. Appendices
Thermal Dissipation
BTU/hr
kCal/hr
22
6
21
5
21
5
88
22
90
23
85
21
103
26
116
29
116
29
152
38
159
40
159
40
260
65
288
73
269
68
313
79
294
74
331
83
27