    N= `lkqbkqp= CONTENTS ...1 APPROVALS...2 WARNINGS ...2 Explanation of graphical symbols ...2 WARNING...2 CAUTION ...2 Important Safety Instructions ...2 User responsibility...3 3.5.1 Speaker damage...3 3.5.2 Speaker output hazard ...3 3.5.3 Radio interference ...3 INTRODUCTION...4 Unpacking ...4 Front Panel ...4 Rear Panel...5 REAR PANEL FEATURES ...6 Gain switch...6 5.1.1...
  • Page 3: Warnings

    WARRANTY...17 O= =^mmols^ip= This equipment conforms to the requirements of the EMC directive 89/336/EEC, amended by 92/31/EEC and 93/68/EEC and the requirements of the Low Voltage Directive 73/23/EEC, amended by 93/68/EEC. Standard Applied P= t^okfkdp= PKN= bñéä~å~íáçå=çÑ=Öê~éÜáÅ~ä=ëóãÄçäë= The lightning symbol within a triangle is intended to alert the user to the presence of un-insulated “dangerous voltage”...
  • Page 4: Front Panel

    14. Do not connect an amplifier output in parallel or series with any other amplifier’s output. Do not connect the amplifier output to any other voltage source, such as battery, mains source, or power supply, regardless of whether the amplifier is turned on or off. 15.
  • Page 5 QKN= råé~ÅâáåÖ= Carefully open the shipping carton and check for any noticeable damage. Every Lab.gruppen amplifier is tested and inspected before leaving the factory and should arrive in perfect condition. If found to be damaged, notify the shipping company immediately.
  • Page 6: Rear Panel

    7. Fan grill filters A grille with foam filters is located on the front panel to prevent dust from entering the amplifier. The grille is removable for easy cleaning of the filter by simply pulling them off. The foam filter should always be used.
  • Page 7: Sensitivity

    R= ob^o=m^kbi=cb^qrobp= Before turning the amplifier on please read the following sections to make sure that the unit is set up properly for your specific application. RKN= d~áå=ëïáíÅÜ= The gain switch located on the rear panel (the central DIP-switch) changes the input sensitivity of the amplifier.
  • Page 8 RKP= léÉê~íáçå=ãçÇÉë= RKPKN= píÉêÉç=ãçÇÉ= In this mode, both channels operate independently of each other. This is used for all 2-channel modes, such as stereo and bi-amping. Set the two center switches to off position for the stereo mode. The level attenuators on the front panel will control the respective channels levels.
  • Page 9: Installation

    Your amplifier uses a forced air cooling system to maintain a low and even operating temperature. All fan cooled Lab.gruppen amplifiers have front to rear airflow. There are several reasons for this, one being that there is usually cooler air outside the rack than inside, and therefore the amplifiers can run at higher continuous power levels without thermal problems.
  • Page 10 referred to on the label. The warranty will not cover damage caused by connecting to the wrong type of AC mains. If the power plug is not appropriate for your country, it can be cut off and wired to a suitable connector in the following way: BLACK or BROWN WHITE or BLUE...
  • Page 11 MAX OUTPUT POWER iP 1350 8 ohms 4 ohms 2 ohms note 1 Average power with music as program source. The amplifier driven to clip level. note 2 Normal music power with 9dB headroom, IEC standard power rating. Table 1. SKSKN= `~äÅìä~íáçå= The heat power can be calculated as in the following example: We consider a headroom of at least 5dB (1/3 of full power) and a 4 ohms load on an amplifier...
  • Page 12 Figure 4. XLR input connector Within the Neutrik® Combojack there is a ¼”(6.3mm) phone jack, which is wired in parallel with the XLR. RING COLD SLEEVE SHIELD/GROUND TKNKO= råÄ~ä~åÅÉÇ=áåéìíë= To connect an unbalanced input source, connect pins 1 and 3 in the cable’s XLR plug (ring and sleeve in a TRS plug).
  • Page 13: Operating Voltage

    They are wired in the following manner: The right jack, Channel A, has both channel A and B outputs, so it’s useful for bridging and bi-amp operation (see bridged mono operation on page 7). The left Speakon, Channel B, carries only the channel B output.
  • Page 14: Indicators

    The two bottom green ”ON” LED’s indicate that the output circuits are receiving the correct rail voltage. V= molqb`qflk=cb^qrobp= Each Lab.gruppen amplifier has many advanced protection features, protecting both the amplifier and the speakers connected to it should a fault condition arise. Under normal use these features are inaudible. All protection circuits are independent.
  • Page 15 VHF protection will re-initiate. VKNKQ= pÜçêí=ÅáêÅìáí=éêçíÉÅíáçå= All Lab.gruppen amplifiers are completely short circuit protected. The protection circuit permits very high peak currents, but still holds the output devices within the safe operation area. If a short circuit is maintained, the channel affected will eventually go into thermal protect cycle until the short circuit has been removed.
  • Page 16: Maintenance

    In the unlikely event of on a non-user rectifiable fault, return the amplifier to your supplier or an approved service centre. Lab.gruppen cannot be held responsible for damage or injury as a result of the top or bottom cover being removed.
  • Page 17 NN=pmb`fcf`^qflkp= i~ÄKÖêìééÉå== ======================== rëÉê=j~åì~ä===ám=NPRM====sÉêëáçå=MKP======OMMPJMOJOR=...
  • Page 18 NO=t^oo^kqv= General his product is manufactured by Lab.gruppen and is warranted to be free from defects in components nd factory workmanship under normal use and service for a period of three (3) years from the date of riginal purchase from an authorised Lab.gruppen dealer.