P031 [Motor NP Volts]
Stop drive before changing this parameter.
Set to the motor nameplate rated volts.
Values
Default:
Min/Max:
Display:
P032 [Motor NP Hertz]
Stop drive before changing this parameter.
Set to the motor nameplate rated frequency.
Values
Default:
Min/Max:
Display:
P033 [Motor OL Current]
Set to the maximum allowable motor current.
The drive will fault on an F7
seconds.
Values
Default:
Min/Max:
Display:
P034 [Minimum Freq]
Sets the lowest frequency the drive will output continuously.
Values
Default:
Min/Max:
Display:
P035 [Maximum Freq]
Stop drive before changing this parameter.
Sets the highest frequency the drive will output.
Values
Default:
Min/Max:
Display:
Related Parameter(s): b004, A084, A085, A086,
Based on Drive Rating
20/Drive Rated Volts
1 VAC
Related Parameter(s): A084, A085, A086, A087,
60 Hz
15/500 Hz
1 Hz
Related Parameter(s): A055, A058, A061, A089, A090,
Motor Overload
if the value of this parameter is exceeded by 150% for 60
Based on Drive Rating
0.0/(Drive Rated Amps × 2)
0.1 Amps
Related Parameter(s): b001, b002, b013, P035, A085,
0.00 Hz
0.00/500.0 Hz
0.01 Hz
Related Parameter(s): b001, b002, b013, P034, A065,
60.00 Hz
0.00/500.0 Hz
0.01 Hz
Programming and Parameters
A086, A087, A110,
A078, A085, A086, A087, A111,
3-9
A087
A090
A098, A114,
A118
A112
A113