Pilot Adjustment; Type 112 Restrictor Adjustment - Fisher EZR Instruction Manual

Pressure reducing regulator with 161ay, 161eb series pilot and type 112 restrictor
Hide thumbs Also See for EZR:
Table of Contents

Advertisement

  2.  Back out the pilot adjusting screw(s).
  3.  For easy initial startup, set the restrictor to the "8"  
position. For future startups, the restrictor can be
left in the desired run position.
4. SLOWLY OPEn the valves in the following order:
a. Pilot supply and control line valve(s), if used
       b.  Inlet block valve
       c.  Outlet block valve
5. For a 161 Series pilot with Type 112 restrictor,
       turn the restrictor(s) to position "2" or to the desired   
run position. For a PRX Series pilot, turn the
       restrictor screw 1 turn counterclockwise from  
       fully seated (turn restrictor fully clockwise then 1  
       turn counterclockwise) and the damper screw 
       fully counterclockwise.
6. For a single regulator, set the pilot to the
desired outlet (control) pressure according to the
pilot adjustment procedure.
For a wide-open downstream monitor
installation, adjust the upstream working 
pilot until intermediate pressure is higher than
the desired setpoint of the monitor pilot. Adjust
the downstream monitoring pilot to the desired
       monitoring takeover pressure.  Reduce the       
upstream pilot to the normal outlet pressure setting.
For a wide-open upstream monitor installation,
       adjust the downstream working pilot to a setpoint  
higher than the setpoint of the monitor pilot.
Adjust the upstream monitoring pilot to the desired
       monitor takeover pressure.  Reduce the downstream  
pilot setting to normal outlet pressure setting.
For a working monitor installation, adjust the
setpoint of the upstream monitor pilot to the desired
       maximum pressure.  Adjust the upstream working  
pilot to the desired intermediate pressure setting.
Adjust the downstream pilot to a pressure setting
slightly above the upstream monitor pilot pressure
setting. Adjust the upstream monitor pilot to its
desired setpoint. The setpoint of the monitor pilot
should be adjusted at least to the guidelines shown
in Table 9. The maximum may be greater. Then,
       establish final desired downstream pressure by  
       adjusting the downstream working regulator pilot.

Pilot Adjustment

For 161 Series pilots, remove the pilot closing cap
(key 16, Figure 19 or key 22, Figure 20) and, on 
161EB Series only, loosen the locknut (key 12, 
Figure 19).  Turn the adjusting screw (key 11, 
Figure 19 or key 35, Figure 20) into the spring case 
(key 2, Figure 19 or key 3, Figure 20) to increase the 
downstream pressure. Turn the adjusting screw out of
the spring case to decrease the downstream pressure.
W4559_1
Figure 6. Restrictor Adjustment
For PRX Series pilots (Figure 27), loosen locknut 
(key 2) and turn the adjusting screw into the spring case 
to increase (or out of the spring case to decrease) the
downstream pressure. When the required downstream
pressure is maintained for several minutes, tighten the
locknut to lock the adjusting screw in position 
and replace the pilot closing cap.
The Restrictor and Damper screws on the PRX Series
pilot control the regulator's proportional band (droop)
and speed of response. Table 7 includes the appropriate
settings for low flow operation.  For additional tuning 
follow the steps outlined below:
1. Start with the restrictor screw 1 turn
       counterclockwise from fully seated (turn restrictor 
       fully clockwise then 1 turn counterclockwise) and  
       the damper screw fully counterclockwise.
  2.  Turn damper screw clockwise until desired  
       performance is achieved.  This reduces the flow  
path of the damper. If the damper becomes fully
       seated (no longer able to turn clockwise) and the  
desired performance has not been achieved, return
       the damper screw to the fully counterclockwise position.
WARnInG
!
The damper screw should not be left in
the fully seated position, as it will lock
the regulator in last position which could
cause incorrect pressure regulation.
3. Turn the restrictor screw an additional turn
       counterclockwise from fully seated.  This increases  
       the flow path of the restrictor.  If additional tuning  
is required, repeat step 2. Follow this method until
desired performance is achieved.

Type 112 Restrictor Adjustment

The Type 112 restrictor controls the regulator's
proportional band (droop) and speed of response. The
restrictor can be used to fine tune the regulator for 
Type EZR