Download Print this page

wattstopper FM-105 Installation Instructions page 2

Line voltage high frequency occupancy sensor

Advertisement

WIRING
Lighting
Load
Metal
shield
MOUNTING OPTIONS
Position metal shield between the FM-105 and lamp. Second op-
tional shield may be mounted to the opposite side of the FM-105.
FM-105
FM-105
Time Delay
Microwave
Microwave
10
30 min
(5.8 GHz)
(5.8 GHz)
sec
Occupancy Sensor
Occupancy Sensor
-
+
Sensitivity
100-277VAC, 50/60 Hz
120/277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
@120VAC: 0-800W Ballast
0-600W Tungsten,
or Tungsten
Light Level
200
(footcandles)
@277VAC: 0-1200W Ballast
1/6 hp
1
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
APPLIANCE
FCC ID: Q4BFM105
CONTROL
88T9
Bottom of FM-105: Align studs on the
bottom of the FM-105 with the holes on
the metal shield flanges. Do not block
wiring terminals on the FM-105 with the
shield.
The mounting foot provides 4 different
mounting positions for use with a single
shield. Only 2 mounting positions can be used with the 2 shields.
FM-105
FM-105
Time Delay
Time Delay
Microwave
Microwave
10
30 min
(5.8 GHz)
(5.8 GHz)
10
30 min
sec
sec
Occupancy Sensor
Occupancy Sensor
-
Sensitivity
-
+
120/277VAC, 50/60 Hz
100-277VAC, 50/60 Hz
+
Sensitivity
@120VAC: 0-600W Ballast,
@120VAC: 0-800W Ballast
0-600W Tungsten,
or Tungsten
Light Level
Light Level
1
200
(footcandles)
@277VAC: 0-1200W Ballast
1/6 hp
200
(footcandles)
1
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
APPLIANCE
FCC ID: Q4BFM105
CONTROL
88T9
Mounting foot: Align 4 corner studs on the bottom of the
FM-105 with 4 corner slots on mounting foot. Twist to secure.
ADJUSTMENTS
Three trimpots on the FM-105 allow you to
adjust the time delay, sensitivity/range, and
light level setpoint. To reduce a setting, turn
the associated trimpot counter-clockwise
toward the minimum setting. To increase a
setting, turn the trimpot clockwise toward the maximum setting.
Warning: Do not overturn the adjustment trimpots!
Time Delay
The FM-105 automatically turns OFF the load after the coverage
area has been vacant for the amount of time set in the time delay.
The minimum setting is 10 seconds, maximum is 30 minutes.
Call 800.879.8585 for Technical Support • www.wattstopper.com
Plastic mounting foot
FM-105
Time Delay
Microwave
(5.8 GHz)
10
30 min
sec
Occupancy Sensor
-
+
Sensitivity
120/277VAC, 50/60 Hz
@120VAC: 0-800W Ballast
or Tungsten
Light Level
@277VAC: 0-1200W Ballast
1
200
(footcandles)
FCC ID: Q4BFM105
APPLIANCE
CONTROL
88T9
Hot/Line
Neutral
FM-105
FM-105
FM-105
FM-105
Time Delay
Microwave
Microwave
10
30 min
(5.8 GHz)
(5.8 GHz)
Microwave
Microwave
sec
(5.8 GHz)
(5.8 GHz)
Occupancy Sensor
Occupancy Sensor
Time Delay
Occupancy Sensor
10
30 min
Occupancy Sensor
-
Sensitivity
sec
+
100-277VAC, 50/60 Hz
120/277VAC, 50/60 Hz
120/277VAC, 50/60 Hz
100-277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
@120VAC: 0-800W Ballast
-
@120VAC: 0-600W Ballast,
+
Sensitivity
@120VAC: 0-800W Ballast
or Tungsten
0-600W Tungsten,
Light Level
0-600W Tungsten,
or Tungsten
1
200
(footcandles)
@277VAC: 0-1200W Ballast
1/6 hp
@277VAC: 0-1200W Ballast
1/6 hp
@277VAC: 0-1000W Ballast,
Light Level
FCC ID: Q4BFM105
@277VAC: 0-1000W Ballast,
1
200
(footcandles)
1/4 hp
FCC ID: Q4BFM105
1/4 hp
APPLIANCE
FCC ID: Q4BFM105
CONTROL
APPLIANCE
88T9
FCC ID: Q4BFM105
CONTROL
88T9
Range/Sensitivity
It is possible for a high frequency sensor to "see" through solid
objects and detect motion if the sensitivity is set too high. If you
are getting detections and the load will not turn OFF, reduce the
sensitivity slightly and see if that corrects the situation.
Light Level
Adjust the daylighting setpoint when ambient light is sufficient
to keep the lights OFF. Set the time delay to minimum. Adjust
the light level trimpot in small increments. Wait 1 to 2 minutes
between adjustments. After the time delay expires and the load
turns OFF, move within the detection area of the sensor. If the
load comes back ON, you need to repeat the procedure.
IMPORTANT START-UP INFORMATION
The first time the sensor is powered-up the load will flash ON
then OFF once, then there will be 10 seconds while the sensor
warms-up. After that time the sensor will work normally.
OR
TROUBLESHOOTING
To quickly test the unit, turn the time delay to minimum. Move
out of the sensor's view. Lights should turn OFF after 10 seconds.
Move into the sensor's view. The lights should turn ON.
Lights do not turn ON:
1. Cover the sensor to simulate darkness then move in the
coverage area. If the load turns ON, adjust the light level.
2. Check all wire connections. Verify all wires are secure.
FM-105
FM-105
Microwave
Microwave
(5.8 GHz)
(5.8 GHz)
Occupancy Sensor
Occupancy Sensor
100-277VAC, 50/60 Hz
120/277VAC, 50/60 Hz
@120VAC: 0-600W Ballast,
@120VAC: 0-800W Ballast
Lights do not turn OFF:
0-600W Tungsten,
or Tungsten
@277VAC: 0-1200W Ballast
1/6 hp
@277VAC: 0-1000W Ballast,
FCC ID: Q4BFM105
1/4 hp
1. If there is no motion in the desired coverage area, the
APPLIANCE
FCC ID: Q4BFM105
CONTROL
88T9
sensor may be picking up movement on the other side of
a wall, partition, window or door. Reduce the sensitivity.
2. Verify time delay and that there is no movement
within the sensor's view for that time period.
FCC NOTICE
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
Caution: Any changes or modifications to this device not
explicitly approved by Watt Stopper could void your authority to
operate this equipment.
Notice: The FM-105 may cause interference to a nearby WIreless
Network operating at a similar frequency around 5.8 GHZ.
WARRANTY INFORMATION
Watt Stopper warranties its products to be free of defects in
materials and workmanship for a period of five (5) years. There
are no obligations or liabilities on the part of Watt Stopper for
consequential damages arising out of, or in connection with, the
use or performance of this product or other indirect damages
with respect to loss of property, revenue or profit, or cost of
removal, installation or reinstallation.
2800 De La Cruz Boulevard, Santa Clara, CA 95050
|
|
|
|
|
FCC ID: Q4BFM105
08745r4 2/2013
Please
Recycle

Advertisement

loading