Download Print this page
laerdal Pocket Mask User Manual

laerdal Pocket Mask User Manual

Advertisement

Quick Links

Use of Mask with Oxygen
Changing Filter
Place Head Strap
Remove Used Filter
1
1
Discard filter
Strapping Mask to face facilitates CPR and
Hold Mask and pull Filter outwards and
sideways, so it separates from Mask.
spontaneous inhalation of oxygen.
Extra oxygen - Connect Oxygen
2
2
Tube to Mask Oxygen Inlet.
Place the mask on a hard, flat surface and
Select oxygen flow (see oxygen chart).
insert a new filter. Firm pressure is required
Provide Mouth to Mask ventilation
to assured that filter is properly attached.
if necessary.
Note
• The mask can be used without filter.
• Ensure the mask is folded when changing filter.
Cleaning and Disinfection
Storage
Warning
The One-way Valve and Filter are designed for
single patient use only. Do not re-use. Re-use
will lead to increased risk of cross contamination,
degradation of performance, and/or device
malfunction. Laerdal is not responsible for any
consequences of re-use.
Mask can be cleaned and disinfected, and
reused after manikin training and patient use.
1.
Wash and scrub in warm soapy water.
2.
Rinse in clean water for min 1 min.
Material Chart
3.
Submerge for 10 minutes in a 0.5%
Mask Filter Valve
Oxygen
Sodium Hypochlorite solution.
inlet
4.
Rinse under running tap water for 3 min.
PVC PP
PC and
PC and
sillicone
sillicone
5.
Allow to dry completely.
rubber
rubber
Not made with natural rubber latex
Patient Use
One-way Valve and filter must be discarded
Oxygen Chart
after single patient use.
Oxygen concentration
O
%
2
After training on a manikin
80
The One-way Valve should be cleaned using
the above procedure after each user session.
54
50
40
Cautions
5
10
• Filter must be discarded after use.
Inhalation by spontaneously breathing patient
• Do not pasteurize, boil or steam autoclave.
Ventilation of non-breathing patient
Technical Specifications
Temperature limits
Operating -10 °C (14 °F) to 40 °C (104 °F)
Storage
-40 °C (-40 °F) to 50 °C (122 °F)
Expiratory resistance for the patient*
Mask & One-way Valve
2.9 cm H 2 O
Mask, Filter & One-way Valve
5.2 cm H 2 O
Inspiratory resistance for the patient*
Mask & One-way Valve
2.4 cm H 2 O
Mask, Filter & One-way Valve
4.7 cm H 2 O
Performance data are nominal values only.
* As per standard test method
Models
Hard
Soft
Poly
This product is in compliance with the essential
case
Pouch
Bag
requirements of EU Council Directive 93/42/
PP
PA
LDPE
EEC as amended by EU Council Directive
2007/47/EC.
82 xx xx
Pocket Mask
w/One-way
Valve and Filter
83 xx xx
Pocket Mask w/
One-way Valve,
Filter, Oxygen inlet
and Head strap
Parts
82 06 10
Filter
82 04 10
One-way Valve
Mask in container
O
flow
2
15
Dimensions 13 cm x 11 cm x 4 cm
(5.1 in x 4.3 in x 1.6 in)
Weight
110 g (4 oz)
Pocket Mask is a trademark of
Pocket Mask
Laerdal Medical AS
© 2017 Laerdal Medical AS.
User Guide
All rights reserved.
Manufactured in China for:
Laerdal Medical AS
P.O. Box 377, Tanke Svilandsgate 30,
4002 Stavanger, Norway
T: (+47) 51511700
Distributed in US by:
Laerdal Medical Corporation
167 Myers Corners Road,
Wappingers Falls, NY 12590, USA
Tel: +1 (800) 431-1055, +1 (845) 297-7770
FAX +1 (800) 227-1143
Distributed in Canada by:
Laerdal Medical Canada LTD,
151 Nashdene Rd., Unit #45
Toronto, ON, Canada, M1V 4C3
T: +1 (416) 298-9600,
Toll free 888/LAERDAL (523-7325)
ou en français (800) 567-9987
Fax: +1 (416) 298-8016
Printed in China
www.laerdal.com
EN

Advertisement

loading

Summary of Contents for laerdal Pocket Mask

  • Page 1 Storage Temperature limits Place Head Strap Remove Used Filter Warning Pocket Mask is a trademark of Operating -10 °C (14 °F) to 40 °C (104 °F) Pocket Mask The One-way Valve and Filter are designed for Laerdal Medical AS Storage -40 °C (-40 °F) to 50 °C (122 °F)
  • Page 2 Caution personal injury or death. Exhalation Exhalation At lower temperatures the Pocket Mask can be Caution harder to unfold. A Caution states a condition, hazard, or If the product becomes too contaminated or difficult to clear, continue with ventilation unsafe practice that can result in minor without the mask.