Natural Gas Hook-Up - ProFire 48G Owner's Manual & Installation Instructions

Table of Contents

Advertisement

GAS REQUIREMENTS
Check with your local gas utility company or with local codes for instructions on installing gas sup-
ply lines. Be sure to check on type and size of run, and how deep to bury the line. If the line is too
small the ProFire gas grill will not function properly. Any joint sealant used must be an approved type
and be resistant to actions of L.P. and Natural gases. Do not forget to place the installer supplied gas
valve in an accessible location. Check local codes. Consult your local gas dealer. In the absence of
local codes, installation must conform to the latest edition of the NATIONAL FUEL GAS CODE, ANSI
Z233.1
The grill is designed to operate on Natural Gas at a pressure of 7" water column (W.C.) (1.75kPa)
unregulated. Check with your gas utility for local gas pressure. Use of your grill at pressures other
than approximate 7" water column could affect the performance of your grill and requires installation of
a natural gas regulator set at 7" W.C.
The grill and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa). The grill
must be isolated from the gas by closing its valves during any pressure testing of the gas supply sys-
tem at test pressures equal to or less than 1/2 psig (3.5kPa).
Never use LP gas in a unit designed for natural gas. If you wish to convert
your grill from one type of gas to the other you may order a gas conversion kit

NATURAL GAS HOOK-UP

Connection: 3/8-flare male fitting in left rear corner of unit
Operating pressure :7.0" W.C.
from ProFire or your dealer.
7