General

Read the section 'Important Safety Information' first.
Providing the shower control has been correctly installed and is operated in
accordance with the instructions contained in this guide, difficulties should not
arise. If any maintenance is required then it must be carried out by a competent
tradesperson for whom the fault diagnosis chart and maintenance instructions
are provided. Before replacing any parts ensure that the underlying cause of the
malfunction has been resolved.
Shower controls are mechanical devices and should be serviced annually depending
on the water conditions. Areas of the country which are affected by hard water should
consider shorter service intervals.
When installed in very hard water areas (above 200 p.p.m. temporary hardness)
your installer may advise the installation of a water treatment device to reduce the
effects of limescale formation.
You may, if you wish, choose to engage the services of a Mira Service Engineer or
Agent, the terms of which are outlined on the back page of this guide.

Cleaning

Many household cleaners contain abrasives and chemical substances, and should
not be used for cleaning plated or plastic fittings. These finishes should be cleaned
with a mild washing up detergent or soap solution, and then wiped dry using a soft
cloth.

Filters

1.
Isolate the hot and cold water
supplies and turn on the flow control
to relieve pressure and drain any
residual water.
2.
U n s c r e w t h e i n l e t a n d o u t l e t
connectors.
3.
Using a 2.5 mm hexagon wrench,
loosen the grubscrew and remove the
shower control from the backplate.
4.
Clean or replace the inlet filters.
5.
Re-assembly is the reversal of the
above procedure.
6.
Restore the hot and cold water
supplies and check for leaks.

MAINTENANCE

16