Mira REALM Installation And User Manual page 12

Thermostatic mixer
Table of Contents

Advertisement

1.
The hot water service must always be
connected to the inlet marked "HOT"
in the base of the shower control
body.
2.
The inlet elbows can be swivelled
to accept rising, falling or back entry
supplies, or any combination of
two.
3.
In choosing the position for the
shower control ensure that the fixed
shower head will be at a suitable
height for the application, and that
there is sufficient vertical distance
between the fixed shower head
and the base of the cold cistern to
produce an acceptable shower.
4.
Important! Flush the incoming
hot and cold water supplies before
connection of the shower control.
5.
Use the 2.5 mm hexagon wrench
(supplied) to loosen the grubscrew
and separate the backplate from the
shower control.
6.
Fix the backplate to the wall with the
supplied fittings if appropriate.
7.
Fit the shower control to the backplate,
align the shower control body as
necessary and tighten grubscrew.
8.
Connect the hot and cold water
supplies to the shower control using
the 15 mm compression fittings.
Note! Care must be taken when
tightening compression nuts so
that you do not damage the plated
surfaces.
Rigid Riser Pipe
Compression
Nut
Olive
Grub Screw
12
Wall Plug
Backplate
Concealing
Plate
Fixing
Screw