Chapter 3 Appendix
SNMP
1500
When installing an OS
Service Control
Manager
7023
When installing an OS
Service Control
Manager
7023
When installing an OS
Service Control
Manager
7030
When installing an OS
Microsoft-Windows-
DistributedCOM
10010
When installing an OS
Microsoft-Windows-
DistributedCOM
10016
When running an OS for the first time
Microsoft-Windows-
WinRM
10149
When installing an OS
Application Event Log
Microsoft-Windows-
Security-SPP
1014
When installing an OS
The SNMP Service encountered an error while accessing the registry
Error
key SYSTEM\CurrentControlSet\Services\SNMP\Parameters\
TrapConfiguration.
If this event is logged only when SNMP is enabled and does not occur
repeatedly, there is no problem with system operation.
Go to the following Microsoft website for details.
http://support.microsoft.com/kb/2002303/
The Network List Service terminated due to the following error.
Error
Device not ready.
This is logged only when the OS is installed and there is no problem
unless the same event logs are continuously logged.
The IP Helper service terminated with the following error:
Error
The service cannot be started, either because it is disabled or because
there are no enabled devices associated with it.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Printer Extensions and Notifications service is marked as interactive
Error
service. However, the system is not allowed to use interactive service.
Thus, this service might not work correctly.
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
The server {xxxxxxxx-xxxx-xxxx-xxxxxxxxxxxx} did not do registration in
Error
DCOM within the necessary timeout period.
For details, refer to the following website:
http://support.microsoft.com/kb/956479/ja (Japanese)
In the settings of application-specific access authorization, access
authorization of local activation for COM server applications with CLSID
{D63B10C5-BB46-4990-A94F-E40B9D520160} and APPID
{9CA88EE3-ACB7-47C8-AFC4-AB702511C276} cannot be granted to
Error
the user NT AUTHORITY SYSTEM SID (S-1-5-18) whose address is
LocalHost (LRPC is used) running with an SID unable to use application
containers (utilization disabled). This security access authorization can
be changed using the component service management tool.
If this is logged at the first boot of OS and the same event log is not
continuously logged, there is no problem.
Warning
The WinRM service is not listening for WS-Management requests.
If this event is logged together with ID 7036 "Service Control Manager
(Windows Remote Management (WS-Management) service has
stopped.), there is no problem in system operation.
Also, if WinRM event 10148 (WinRM service is listening
WS-Management requests.) is output immediately after this event, there
is no problem in system operation.
Failed to obtain end-user license.
Error
hr=0x80072EE7
If this event is logged only when installing an OS and does not occur
repeatedly, there is no problem in system operation.
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
2. List of Windows Event Logs