NEC Express5800/R110i-1 Maintenance Manual page 194

Express server express5800 series
Hide thumbs Also See for Express5800/R110i-1:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C127
BMC eMMC format corrupted.
C128
BMC is in Update Mode.
C200
The error occurred during
memory configuration check.
C201
Memory Configuration change
is detected.
The error occurred during
C202
CPU configuration check.
C203
CPU Configuration change is
detected.
C300
Out-of-band setup
configuration failure
C321
System power consumption is
out-of-range in BBUs
C501
Intel(R) Node Manager is in
Recovery Mode
C600
Internal Flash is not valid. Selected Internal Flash Memory
C624
Invalid internal BIOS
Configuration Data.
C625
BIOS Configuration Data Send
Error.
C626
BIOS Configuration Data Read
Error.
C627
BIOS Configuration Data
Write Error.
C628
System configuration data
cleared by System Boot
Options command.
194
Description
A format error occurred on BMC
eMMC.
BMC is in update mode.
The memory information could not
be obtained.
The memory configuration has
changed since the previous
startup.
The CPU information could not be
obtained.
The CPU configuration has
changed since the previous
startup.
Invalid access to BMC Mezzanine
card
Over capacity of system power
capacity.
The Recovery Mode of Intel Node
Manager was detected.
as an onetime booting device but
unable to enable it.
Internal error of BIOS
Configuration Data was detected.
An internal error was detected
during sending BIOS
Configuration Data.
An internal error was detected
during reading BIOS Configuration
Data.
An internal error was detected
during writing BIOS Configuration
Data.
The SETUP setting was cleared
by Set System Boot Options of the
standard IPMI command.
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
Action
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
Turn off the power and restart the server.
When Check previous system Config is
enabled in server of the BIOS settings, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no configuration
change has been made, contact your sales
representative.
Turn off the power and restart the server.
When Check previous system Config is
enabled in server of the BIOS settings, this
message appears if the configuration was
changed since the previous startup. If this
message appears even when no configuration
change has been made, contact your sales
representative
Contact your sales representative.
Check the jumper switch on the motherboard.
Unplug the power cable, wait for at least 30
seconds, and then restart the server.
Turn off the power, disconnect the server from the
outlet, wait for at least 30 seconds, and restart the
server.
Run SETUP, and then specify the necessary
settings.
1. POST Error Message
(5/5)