3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7 feet (2.13m) from the floor and
30in. (76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a downrod
on a regular (no-slope) or vaulted ceiling. The
hanging length can be extended by purchasing
a longer downrod (0.5in. /1.27cm diameter).
Other installation, such as flushmount, is NOT
available for this fan.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from breaker panel
and be sure operating light switch is turned to the OFF
position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure the outlet
box is securely attached to the building structure and can support
the full weight of the fan. Ensure outlet box is clearly marked
"Suitable for Fan Support." If not, it must be replaced with an
approved outlet box. Failure to do so can result in serious injury.
CAUTION: Be sure outlet box is grounded properly and that a
ground wire (GREEN or bare) is present.
Partially loosen screws in slotted holes of canopy. Remove the
other 2 screws--save for later use. Twist canopy to remove
hanging bracket.
Install hanging bracket to outlet box using original screws,
spring washers and flat washers provided with new or original
outlet box.* If installing on a vaulted ceiling, face opening of
hanging bracket towards high point of ceiling. Arrange
electrical wiring around the back of the hanging bracket and
away from the bracket opening.
*Note: It is very important that you use the proper hardware
when installing the hanging bracket as this will support the fan.
blade edge
30
inches
7 feet
(76cm)
(2.13m)
downrod
installation
hanging bracket
flat washers
outlet box screws
page 3
12 ft. - 20 ft.
(3.66m - 6.1m)
flushmount
installation
Vaulted ceiling
angle is not to
exceed 25 degrees.