Dmx Control - MAGIC FX SMOKEBUBBLE BLASTER MFX1603 User And Installation Manual

Table of Contents

Advertisement

1.6

DMX CONTROL

When connected to DMX and with Manual mode OFF the MAGICFX
controlled with 1 safety address and 4 operational addresses:
DMX Address
Safety address
Start address (Bubble setting)
Start address + 1 (Smoke setting)
Start address + 2 (Fan speed)
Start address + 3 (Go trigger)
The safety address cannot be the same as (one of) the operational address(es). Operating of
these addresses results in the following:
DMX Address
Safety address
Start address
(Bubble setting)
Start address + 1
(Smoke setting)
Start address + 2
(Fan speed)
Start address + 3
(Go trigger)
When you link multiple machines with DMX, we advise you to use the same safety address for all
machines.
Always plug in a DMX Terminator into the DMX output of the final unit in the
CAUTION
control sequence. Using a DMX Terminator improves signal reliability.
10
MAGICFX® SMOKEBUBBLE BLASTER — User and Installation Manual
Address range
1 - 512
1 - 512
1 - 512
1 - 512
1 - 512
DMX addresses
DMX Value (decimal)
0
99
100
155
156
255
0
127
128
255
0
85
86
170
171
255
0
9
10
255
0
199
200
255
SMOKEBUBBLE BLASTER is
®
Result
Device disabled
Device enabled
Device disabled
50% bubble capacity
100% bubble capacity
No smoke
50% of bubbles contain smoke
100% of bubbles contain smoke
Fan OFF
Minimal speed -> Full speed
Effect OFF
Effect ON
Operation of the DMX addresses