Table 2-1 (Cont.): Basic Troubleshooting
Symptom
Possible Cause
Screen display is dis- Green signal cable has loose
torted, flickering, or rolling, connection, or is not connected
to the monitor or the sys
tem.
Red or blue color is miss
ing.
Screen displays foreign
colors (bad purity).
Red or blue signal cable has
loose connection, or is not con
nected to the monitor or sys
tem.
System or cable for the miss
ing color is faulty.
Ver
ify this problem by swap
ping the red and blue sig
nal
cables
on
the
moni
tor.
If the missing color re
turns, the system or the ca
ble for the missing color is
faulty.
Monitor
is faulty.
Ver
ify this problem by perform
ing the same procedure de
scribed in the previous step. If
the missing color does not re
turn, the monitor is faulty.
Monitor has been swiveled.
Suggested Solution
Refer to VAXstation 2000
Hardware Installation
Guide for correct proce
dures to install the ca
bles.
Reconnect the
green signal cable.
Monitor or system is
faulty. Turn the mon
itor and system off.
Contact Field Service.
Refer to the VAXsta
tion 2000 Hardware In
stallation Guide for cor
rect procedures to in
stall the cables. Recon
nect the red or blue sig
nal cable.
Turn the monitor and
system
off.
Con
tact Field Service.
Turn the monitor off.
Contact Field Service.
Press degauss
for 5 seconds.
switch
Caution: Before moving the monitor, turn the monitor off and wait 20 sec
onds to allow static electricity on the CRT to dissipate.
2-6