5 Configuring the Reciter

5.1 Configuring the Auxiliary Power Supply and External Reference.

Service Kit Menu Item (SK): Configure > Base Station > Miscellaneous
Configure the following
parameters.
Telephone:+64-3-357-9991
support@taitworld.com
http://support.taitworld.com
The specific changes that you will need to make to the TB8100 base
station's configuration file (using the Service Kit application) are as follows.
(For further information on using the Service Kit, please refer to the Service
Kit User's Manual or the online help). The following procedure assumes the
use of the default template, available in File > New and choose the
default.t8t file.
1. Set auxiliary power supply to 'Task Manger '.
2. Select the relevant external reference frequency, either 10 MHz or
12.8 MHz.
TN-1013-AN
Date of Print: 12/03/07
Tait Electronics Ltd
Select Frequency of
External Reference to
10MHz or 12.8MHz.
Aux power Control set to
Task Manager.