Connection Instructions; Liquid Propane Cylinder Requirements; Connecting The Liquid Propane Cylinder - Nexgrill 820-0062H Owner's Manual

Fortress 2 burner cast aluminum table top gas grill
Table of Contents

Advertisement

GAS HOOK-UP
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement pressure regulator
and hose assembly must be specified by the grill manufacturer. This grill is configured for liquid propane. Do not use a
natural gas supply.
Periodic routine inspection of the regulator hose assembly should be performed at least once per year to discover potential
wear, deterioration, or damage that could allow gas to leak. We recommend replacement of the regulator hose assembly
every five (5) years, or sooner if wear, deterioration, or damage is discovered.
Total gas consumption (per hour) with all burners set on "HIGH":
EACH BURNER
TOTAL
Only use liquid propane cylinders with a capacity of 9 kg or less. A 9 kg cylinder's size is
approximately 310 mm in diameter and 480 mm in height. Dimensions vary depending on liquid
propane cylinder manufacturer. The cylinder outlet should be left hand POL thread.
A dented or rusty liquid propane cylinder may be hazardous and should be checked by your
supplier. Never use a cylinder with a damaged valve. The liquid propane cylinder must be
constructed and marked in accordance with the specifications for liquid propane cylinders that
adhere to national regulations for the country of use. The gas cylinder must have a shut-off valve
terminating at the valve outlet. Routine check on the cylinder inspection expiry date is required.
Storage indoors of an outdoor cooking gas appliance indoors is permissible only if the cylinder is
disconnected and removed from the outdoor cooking gas appliance. The cylinder system must be
arranged for vapour withdrawal. The cylinder must include a collar to protect the cylinder valve.
The gas appliance inlet connection is 3/8" SAE Flare with 5/8-18 UNF thread.
Manifold pressure: (operating) 27.9 cm (11 in) water column, (non-operating) 28.4 cm (11.2 in) water
column.
If fitted, remove the plastic valve cover from the liquid propane cylinder. Make sure the gas hose
does not contact the grease pan or grill firebox when the liquid propane cylinder is positioned.
WARNING:
NEVER ATTEMPT TO USE DAMAGED OR OBSTRUCTED EQUIPMENT. SEE YOUR LOCAL LIQUID PROPANE
DEALER FOR REPAIR.
REPLACING THE LIQUID PROPANE CYLINDER
Turn the grill burner valves clockwise to "OFF" () and make sure the grill is cool.
Turn the liquid propane cylinder valve to the CLOSED position by turning clockwise
until it stops.
Detach the regulator assembly from the cylinder valve by turning the connection
clockwise.
Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only
install the type of dust cap on the cylinder valve outlet that is provided with the
cylinder valve. Other types of caps or plugs may result in leakage of propane.
6.86 MJ/H
13.72 MJ/H

CONNECTION INSTRUCTIONS

LIQUID PROPANE CYLINDER REQUIREMENTS

CONNECTING THE LIQUID PROPANE CYLINDER

9 KG CYLINDER
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents