Location Requirements

Select a location that provides minimum exposure to wind and
traffic paths. The location should be away from strong draft
areas.
Do not obstruct the flow of combustion and ventilation air.
Clearance to combustible construction for the grill:
A minimum of 92 cm (36 in) must be maintained between
the front of the grill hood, sides, and back of the grill and
any combustible construction.
The grill shall not be used under overhead combustible
construction.

Gas Supply Requirements

GAS AND REGULATOR INFORMATION
Bottle sizes of 4.5-9.0 kg are recommended for use with this
BBQ. Suitable regulators must have an outlet pressure of 2.75
kPa / 0.40 psi. You must have the proper regulator and bottle
for the BBQ to operate safely and efficiently. Where applicable,
routine inspection of the gas cylinder to check test date status.
Do not use disposable gas cylinders.
PLEASE NOTE THE HOSE AND REGULATOR SUPPLIED
WITH THIS BBQ ARE OF AN APPROVED TYPE AND ARE
SPECIFICALLY DESIGNED FOR USE WITH YOUR BBQ.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local
codes and ordinances. In the absence of local codes,
installation must conform with code AS/NZS 5601.1.
Refer to the model/serial rating plate for information on the type
of gas that can be used. If this information does not agree with
the type of gas available, check with your local gas supplier.
Gas Conversion:
No attempt shall be made to convert the grill from the gas
specified on the model/serial rating plate for use with a different
gas type without consulting the serving gas supplier.
Gas Pressure Regulator
The gas pressure regulator supplied with this grill must be used.
The inlet (supply) pressure to the regulator should be as follows
for proper operation:
LPG Gas:
Operating pressure: 2.75 kPa / 0.40 psi.
Inlet (supply) pressure: 2.75 kPa / 0.40 psi.
Contact local gas supplier if you are not sure about the inlet
(supply) pressure.
Gas Supply Line Pressure Testing
Testing above 3.5 kPa / 1/2 psi (gauge):
The grill and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of that system at test pressures greater than 1/2 psi (3.5 kPa).
Testing below 3.5 kPa / 1/2 psi (gauge) or lower:
The grill must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal
to or less than 3.5 kPa / 1/2 psi.

Gas Connection Requirements

Liquified Petroleum Gas bottle
This grill is equipped for use with a 9.0kg LPG bottle (fuel bottle
not supplied). A gas pressure regulator/hose assembly is
supplied.
Any brand of 9.0kg LPG bottle is acceptable for use with the
grill, provided that it is compatible with the grill's retention
means.
It is also design-certified by AGA for local LP gas supply.
A. Gas pressure regulator/hose assembly
The LPG bottle must be mounted and secured.
LPG Gas Conversion Using a Local LPG Gas Supply
If you want to convert to local LPG gas supply, contact your
local gas company for specific instructions.
7