Technical data and limit values
5.3 Version
The Ethernet system MSX-E1516 is available in the following versions:
The specific version name can be found on the type label of your Ethernet system (see also Chapter 1.1
of the general MSX-E manual).
5.4 Limit values
Height:
Operating temperature:
Storage temperature:
Relative air humidity
at indoor installation:
Current supply:
Nominal voltage:
Supply voltage:
Current consumption (at 24 V):
Safety:
Degree of protection:
Optical isolation:
Reverse polarity protection:
1 The degree of protection is only provided when the relevant protection caps are used.
www.addi-data.com
NOTICE!
The connection lines must be installed in such a way that they are
protected against mechanical loads.
Table 5-1: MSX-E1516: Versions
Version
MSX-E1516
MSX-E1516-NPN
NOTICE!
After boot-up, the MSX-E system should warm up for a minimum
15 minutes so that a constant internal temperature will be
reached.
Features
16 digital inputs/outputs, 24 V
16 digital inputs, 24 V (NPN)
2000 m over NN
-40 °C to +85 °C
-40 °C to +85 °C
50 % at +40 °C
80 % at +31 °C
(Ice formation from condensation must be
prevented.)
24 VDC
18-30 V
200 mA ± 10 %
(when the outputs are switched off)
1
IP 65
1000 V
1 A max.
22
MSX-E1516