Never use the mains plug or an external timer as a switch to start and stop the air conditioning unit. Use
the provided ON/OFF button located on the control panel.
Always place the unit on a dry and stable surface.
The appliance should not be installed in laundry or wet rooms
The appliance must be placed in a room without sources of ignition (for example: open flames, an
operating gas appliance or an operating electric heater).
R290 refrigerant gas complies with European environmental directives. R290 has a low GWP (Global
Warming Potential) of 3.
This appliance contains about 210 g of R290 refrigerant gas.
Do not use or store in unventilated spaces with an area smaller than 10.1 m
such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or
explosion hazard should the refrigerant come into contact with electric heaters, stoves or other sources
of ignition.
Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may
have compromised the refrigerant system.
Refrigerant gas may be odourless.
Do not open the air conditioner, to attempt service or repair the unit. Any internal servicing of the unit
must be carried out only by the manufacturer or its authorized technicians.
Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before
opening and servicing the unit the authorized engineer must be in possession of a copy of the
manufacturer's service manual and must follow the safety information contained within it to ensure all
hazards are minimized.
The refrigerant system should not be perforated or punctured.
Energy Saving and Unit Safety Protection Tips
Do not cover or restrict the airflow from the outlet or inlet grills.
For maximum performance the air conditioner should be situated at least 50cm from the walls or other
objects.
Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks
(approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary,
depending on the air quality.
For the initial start-up set the fan speed to maximum and the thermostat to 4-5 degrees lower than the
current temperature. After, set the fan switch to low and set the thermostat to your desired setting.
To protect the unit we recommend the unit should only be used when the room temperature is between
7°C and 35°C. If the temperature is below this use electrical heating to raise the temperature above 10⁰C
before starting the unit.

FEATURES AND PARTS LIST

Page 4 of 18
2
per unit. The room must be