Download Print this page

Other Information - Bosch DS415i Installation Instructions Manual

Photoelectric intrusion detection system

Advertisement

4.0 Alignment
NOTE:
The use of an AL402 Alignment Light is suggested in the
alignment of this detector.
Transmitter Alignment:
Mount the AL402 Alignment Light to the Receiver and connect the
two AL402 leads to the spade lugs on the receiver power
terminals (1 and 2).
Viewing Port
Adjust the AL402 until the flashing light falls directly on the
Transmitter. Lock the AL402 into place.
At the Transmitter, unlock the optical module
by swinging the locking lever forward. Look
through the viewing port on the side of the
optical module and align the optical module
until the flashing light from the AL402 falls
completely through the hole in the white image
plane.
Lock the optical module in place by returning the locking lever to
its original position.
Insert the module seal if extra bug and dust immunity is desired.
Receiver Alignment:
Remove the AL402 from the Receiver and mount it on the
Transmitter. Connect the two AL402 leads to the Transmitter
power terminals (1 and 2).
Adjust the AL402 until the flashing light falls directly on the
Receiver.
At the Receiver, unlock the optical module by swinging the locking
lever forward. Align the optical module until the flashing light
from the AL402 falls completely through the hole in the white
image plane.
Remove the AL402 from the Transmitter.
Fine Peak Alignment:
Fine peak the Receiver alignment by connecting a VOM on its
lowest DC voltage scale to the Peaking Voltage Tests points on
the Receiver using a TC6000 Test Cord.
Adjust the Receiver's optical module until the highest voltage is
shown on the meter.
Lock the optical module in place and remove the meter.
Insert the module seals if desired.
© 2008 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, New York, USA 14450-9199
(800) 289-0096
Margin Test Switch:
The Margin Test Switch on the Receiver helps ensure that the detec-
tor is aligned properly by decreasing the signal into the Receiver
when pressed.
Locking Assembly
5.0 Setup And Walk Testing
AL402
AL402 Bracket
Spacer
NOTE:
6.0 Battery Connection/Testing
NOTE:
Align Light
Through Hole
Image Plane
T
7.0 Alarm Retransmission Circuit Testing

8.0 Other Information

Maintenance:
Testing:
Press and hold the Margin Test Switch. Be careful not to block
the beam when pressing the switch.
The Alarm LED should remain OFF while pressing the Margin
Test Switch. If the LED goes ON, the alignment is insufficient and
the detector should be realigned.
Place the covers on both units.
Walk test the system by passing between
the Transmitter and Receiver at several
points in the coverage area. Take care to
ensure that the beam is parallel to the floor
and not reflecting off of polished floors or
walls.
The infrared beam may be reflected off of shiny objects,
walls, or floors. It is extremely important to walk test the
system at all points that coverage is expected.
The battery is for AC Units Only. Do not install the battery on
DC powered units.
The P333 Battery is supplied as backup power when the unit will
be powered from a transformer.
Plug the battery connector into the battery pins on the unit.
Unplug the AC Transformer at the Transmitter and observe the
Receiver's Alarm LED.
he Receiver's Alarm LED should remain OFF
Walk test the units by walking between the Transmitter and
Receiver. Insure that the Receiver's alarm LED lights when the
beam is blocked.
Unplug the Receiver's Transformer and repeat the walk test.
Plug both Transformers back in.
If the retransmission circuit is used, Activate the devices connected
to the retransmission circuit and observe the Receiver's alarm
LED.
NOTE: The Receiver's alarm LED should light and the alarm relay
should transfer when devices connected to the
retransmission circuit are activated.
At least once per year, the front covers of both units should be
cleaned using a commonly available window cleaner, and a soft,
dry cloth.
The end user should be instructed on the proper test procedures
and frequency.
The only way to insure continued daily operation of any intrusion
detection system is to perform regular walk tests of the coverage
area.
WHITE
RED
BLACK
TC6000
08/08
DS415i Installation Instructions
P/N: F01U068107-07 Page 2