1.0 General Information

Description:
The DS415i is a pulsed active infrared photoelectric intrusion detection
system designed to provide an alarm activation upon the detection of
an intruder passing through its beam. It consists of a separate
Transmitter and Receiver and is capable of coverage ranges up to
500 ft. (150 m). The Transmitter emits an invisible, pulsed infrared
beam which is received by the Receiver. If an intruder passes between
the Transmitter and Receiver, causing a beam blockage for a minimum
of 55 ms, the Receiver will indicate an alarm. The DS415i receiver
and transmitter are intended to be mounted indoors only.
Battery
Pins
Alarm LED
Specifications:
Input Power:
8 to 14.5 VDC or 12 VAC.
NOTE:
For DC input applications connect the unit only to a UL Listed
power supply or control unit capable of providing at least 4 hours
of standby time. For UL certificated, AC input applications the
TR12 transformer and P333 battery pack shall be used.
The model DS415iDC detectors are identical to the model
DS415i except the DS415iDC is intended to be connected to
a 12 VDC power source. The power source should only be a
UL Listed power supply or control unit within the range of 8 to
14.5 VDC.
Since the DS415iDC does not contain an internal standby
battery, the power source should be capable of providing at
least 4 hours of standby time in the event primary power is lost.
Current Draw:
Transmitter - 8 mA @ 12 VDC.
68 mA RMS with battery.
Receiver - 33 mA @ 12 VDC.
95 mA RMS with battery
Range:
500 ft. (150 m).
Alarm Output:
Form "C" Rated at 125 mA @ 28 VDC.
Tamper Output:
Normally Closed Rated at 125 mA @
28 VDC.
Temperature:
Storage and operating temperature range
is 0°F to +120°F (–18°C to +49°C). For UL
installations the operating range is +32°F
to +120°F (0°C to +49°C), indoor use.
Locking Lever
Optical Module
Margin Test Switch
Peaking Voltage
Test Pins
Tamper Switch
Terminal Strip
Optional Accessories:
The AE405 and M402A shall not be used in UL Certificated
Installations.
2.0 Mounting
Choose a location where an intruder entering the area will have to
cross between the Transmitter and the Receiver.
Mounting surface should be rigid, and selected as to offer a clear
line of sight between the Transmitter and Receiver.
Remove the cover of the Transmitter and, using the back of the
chassis as a template, locate and mark the four keyed mounting
slots on the mounting surface.
Prestart the mounting screws in the mounting surface, attach and
secure the chassis to the mounting surface.
Repeat the mounting procedure using the Receiver.
3.0 Wiring
Wire the Transmitter and Receiver as shown.
Receiver Wiring
Input Power
8 - 15 VDC
or 12 VAC
- +
1
Transmitter Wiring
Input Power
Alarm Retransmission Circuit Information:
The Transmitter allows connection of normally open or normally
closed contacts to a supervised alarm retransmiss circuit. Alarm
retransmission allows dry contact devices such as door or window
contacts to be wired into the Transmitter using it as a relay path to
the Receiver without additional wiring to the Control Panel.
Retransmission Wiring:
Transmitter Terminals
3
4
N/O
TR12 Transformer, AL402
Alignment light, P333 Standby
Battery, C6000 Test Cord,
AE405 splash Resistant
Enclosure, M402A Mirror.
Tamper
Alarm
2
3
4
5
6
7
8 - 15 VDC
or 12 VAC
Retransmission
- +
Circuit
1
2
3
4
E
1 KΩ End of Line
O
Resistor
L
Alarm
Alarm
N/C
N/C
E
1 KΩ EOL
O
N/O
Resistor
L

Advertisement

loading

Summary of Contents for Bosch DS415i

  • Page 1: Installation Instructions

    • Remove the cover of the Transmitter and, using the back of the of 55 ms, the Receiver will indicate an alarm. The DS415i receiver chassis as a template, locate and mark the four keyed mounting and transmitter are intended to be mounted indoors only.
  • Page 2: Other Information

    The only way to insure continued daily operation of any intrusion • Insert the module seals if desired. detection system is to perform regular walk tests of the coverage area. © 2008 Bosch Security Systems, Inc. 08/08 130 Perinton Parkway, Fairport, New York, USA 14450-9199 DS415i Installation Instructions (800) 289-0096...