Furuno DRS4DL+ Installation Manual page 11

Radar sensor
Table of Contents

Advertisement

• The cable must be secured so no tension is applied to the connectors. To pre-
vent tension, create a loop in the cable close to the sensor and secure the loop
with cable ties, as shown in the figure below.
• Wrap the junction of the connectors with self-vulcanizing tape for waterproofing.
• Using a cable tie, fasten the cable to the mast, etc. at the neck of each connec-
tor.
6. Connect the LAN connector of the cable assembly to a LAN port on the FURUNO
Multi Function Display or Ethernet HUB.
Ethernet Hub
or
Multi Function Display
7. Connect the power wires to the ship's battery (12 VDC or 24 VDC).
• Red wire: Connect to the positive terminal. The red wire has the fuse holder.
• Blue wire: Connect to the negative terminal.
• Black wire: The black wire is a shielding wire for grounding.
Ship's battery
(12 VDC /
24 VDC)
Loop cable and secure loop with cable ties.
The minimum bend radius is 80 mm.
Connect cables
Wrap junction and connectors with tape.
LAN connector
Distribution
switchboard
Shield
LAN cable
5
1. INSTALLATION
Cable Assy.
Fuse holder
Red
Blue
Cable assembly
Black
To antenna unit

Advertisement

Table of Contents
loading

Table of Contents