Viewing Additional; Bump Test (Bump Page) - MSA ALTAIR 5X Operating Manual

Msha-multigas detector
Hide thumbs Also See for ALTAIR 5X:
Table of Contents

Advertisement

2.4
Viewing Additional Pages
The Main Screen appears at device turn-ON.
Additional displays can be viewed by pressing the  button to move to the screen as indicated by the
"soft key".
(For the monochrome display, the name of the page is displayed.)
The sequence of pages are as follows and are described below:
MAIN
MEASURE
PAGE
Advance on
WIRELESS **
Advance on
MOTION
ALERT
STATUS *
2.4.1

Bump Test (BUMP Page)

This page allows the user to perform an automated Bump Test on the device. To perform the test, the
q (YES) button is pressed.
See section 3.7 for details on performing the Calibration Check.
If the  button is pressed, the Bump Test is not performed, and the display shows the next page in the
sequence (PEAK).
If the  button is pressed, the Bump Test is not performed, and the display reverts back to the normal
MEASURE page.
Advance on
BUMP TEST ?
* IF ENABLED
** IF WIRELESS IS INSTALLED
1
NOT VALID FOR ALL SENSORS
CAL DUE
DATE *
ALTAIR 5X MSHA
PEAK *
STEL *
TWA *
LAST CAL
DATE
DATE *
Description