6.2.1.4

Indicators on the HDDs

Figure 24: Indicators on the 2.5 inch HDD modules
1
HDD/SSD FAULT indicator (orange)
(in conjunction with a RAID controller)
– Does not light: no HDD error
– Lights up: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing, a rebuild process was stopped or the HDD module is not
correctly inserted)
– Slow flashing: HDD Rebuild (the data is being restored after changing
a drive)
– Fast flashing: HDD Identify
– Four fast blinks/pause: HDD Predicted Fault
– Two fast flashes/pause: HDD Hot Spare (Hot spare drive active. The
corresponding drive has failed).
2
HDD/SSD BUSY indicator (green)
– Lights up: HDD in active phase
– Does not light: HDD inactive (drive inactive)