Connecting solar modules (DC) – 1-/2-MPPT operation M88H_121 (ST)
DANGER
Modified design of the DC inputs
The design of the DC inputs on the DC terminal
block has changed in comparison with previous
versions of the M88H_121 (ST)!
► You must comply with the correct use of plus
(+) and minus (-) when connecting the DC
cables.
The M88H_121 (ST) is designed by default for operation with 2
MPP trackers (MPPT). To accomplish this, the operating point
for the two DC inputs is adjusted separately. In cases of 2-MPPT
operation, two cables are connected per DC input (DC1 and
DC2), one each for DC+ and DC–.
DC cabling for 2 MPPT operation when using aluminum cables
with Al-Cu crimped connectors
As an alternative, the M88H_121 (ST) can be operated with only
1 MPP tracker. If this is the case, then the DC connection pro-
ceeds with only 2 cables (1 cable each for DC+ and DC–).
Phoenix Contact jumper for operation with 1 MPP tracker
In addition, 2 jumpers from Phoenix-Contact are required (Phoe-
nix order number EB 2-31/UKH - 0201388 for UKH 150). The
jumpers are not included in the scope of delivery and must be
ordered separately from commercial outlets