Planning The Installation - Delta M88H_121 (ST) Quick Installation Manual

Solar power inverter; st product version j; cf product version d
Table of Contents

Advertisement

Planning the installation

Installation location of the inverter
► Attach the inverter so that the information on the display
can be read and the buttons can be operated without any
problems.
Mounting alignment
Outdoor installations
► The inverter has a protection degree of IP65 and can be
installed indoors and outdoors. Despite this, the inverter
should be protected by a roof against direct solar irradia-
tion, rain and snow. For example, the power of the inverter
will be reduced if it is too heavily heated by solar radiation.
This is normal operating behavior for the inverter and is
necessary to protect the internal electronics.
14
Mounting without mounting rack
≤90°
► The inverter is very heavy. The wall
or mounting system must be able
to bear the heavy weight of the
inverter.
► Always use the mounting plate sup-
plied with the inverter.
► Use mounting materials (dowels,
screws etc.) that are suitable for the
wall or the mounting system, as well
as the heavy weight of the inverter.
► Mount the inverter on a vibration-
free wall to avoid disruptions.
► When using the inverter in residen-
tial areas or in buildings with ani-
mals, possible noise emissions can
be disturbing. Therefore, carefully
choose the place of installation.
► Mount the inverter on a fireproof
wall.
≥15°
Quick Installation Guide for Solar Power Inverter M88H EU V3 EN 5013240202 02 2018-03-22
Mounting with mounting rack
0° ... 90°