TECHNICAL SPECIFICATIONS/CERTIFICATIONS
Sensor
Carbon
Monoxide
Hydrogen
Sulfide
Sulfur
Dioxide
Nitrogen
Dioxide
Ammonia
Phosphine
Hydrogen
Cyanide
Chlorine
Chlorine
Dioxide
54
Range
Resolution
0 - 999 ppm
1 ppm CO,
CO
for 0 to 500
ppm CO
0 - 200 ppm
1 ppm H
H
S
3 to 200 ppm
2
H
S
2
0 - 20. ppm
0.1 ppm SO
SO
2
0 - 20. ppm
0.1 ppm NO
NO
2
0 - 100. ppm
1 ppm NH
NH
3
0 - 5.0 ppm
0.05 ppm PH
PH
3
0 - 30.0 ppm
0.5 ppm HCN
HCN
0 - 20.0 ppm
0.1 ppm Cl
Cl
2
0 - 1.00 ppm
0.02 ppm ClO
ClO
2
ALTAIR 5 - Operating Manual
Reproducibility
normal temperature
range:
± 5 ppm CO or 10 %
of reading, whichever
is greater
0 to 300 ppm CO
± 15 % >300 ppm CO
extended temperature
range:
± 10 ppm CO or 20 %
of reading, whichever
is greater
S, for
normal temperature
2
range:
± 2 ppm H
2
of reading, whichever
is greater
0 to 100 ppm H
± 15 % >100 ppm H
extended temperature
range:
± 5 ppm H
2
of reading, whichever
is greater
2
2
3
3
2
2
Response
time
60 second
(normal
temperature
range)
60 second
(normal
S or 10 %
temperature
range)
S
2
S
2
S or 10 %
MSA