Copyright 2002 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Ethernet and Fast Ethernet Media Converters Model Numbers: AT-MC115XL, AT-MC116XL This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 4
Electrical Safety and Emission Compliance Statement RFI Emission EN55022 Class B Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Immunity EN55024 Warning: This product requires shielded cables to comply with emission and immunity standards.
Table of Contents Electrical Safety and Emission Compliance Statement ......iii Welcome to Allied Telesyn ................. vii Where to Find Related Guides................. vii Document Conventions ..................vii Contacting Allied Telesyn Technical Support..........viii Online Support ..................viii Telephone Support ...................viii E-mail Support ..................viii Returning Products ...................
Page 6
Table of Contents Chapter 2 Installing the Media Converter ..............11 Verifying the Package Contents ..............11 Planning the Installation ................. 11 Selecting a Site ..................12 Reviewing Safety Guidelines ..............13 Installing the Media Converter................ 14 Warranty Registration ..................16 Chapter 3 Troubleshooting ...................
Welcome to Allied Telesyn This guide contains instructions on how to install the AT-MC115XL and AT-MC116XL Ethernet and Fast Ethernet Media Converters. Where to Find Related Guides The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy way to access the most recent documentation, software, and technical information for all of our products.
Welcome to Allied Telesyn Contacting Allied Telesyn Technical Support You can contact Allied Telesyn technical support online or by telephone or e-mail. Online Support You can request technical support online by accessing the Knowledge Base at http://kb.alliedtelesyn.com. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-MC115XL and AT-MC116XL Installation Guide Returning Products Products for return or repair must first be assigned a Return Materials Authorization (RMA) number. A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender’s expense.
Welcome to Allied Telesyn For Sales or Corporate Information You can contact Allied Telesyn for sales or corporate information at the location below: Allied Telesyn, Inc. 19800 North Creek Parkway, Suite 200 Bothell, WA 98011 Tel: 1 (425) 487-8880 Fax: 1 (425) 489-9191 Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the General Enquiry Form...
Both ports can operate at either 10 Mbps or 100 Mbps and feature half- and full-duplex operation. The AT-MC115XL and AT-MC116XL media converters can be used on a desktop or in an AT-MCR12 chassis. These units are easy to install and do not require software configuration or management.
Page 12
Figure 2 illustrates an AT-MC116XL media converter. Figure 2 AT-MC116XL Front Panel (SC Connector) Table 1 lists the maximum operating distances for the AT-MC115XL and AT-MC116XL media converters. The maximum distance of the fiber optic port depends on the operating speed.
Standard size for use on a desktop or in an AT-MCR12 rackmount chassis Status LEDs Table 2 lists the LEDs for the media converters. Table 2 AT-MC115XL and AT-MC116XL LEDs Color Description Green Power is applied to the media converter.
100Base-SX port. The fiber optic port features either an SC or ST connector, depending on the model. The maximum operating distance for the fiber optic port for both the AT-MC115XL and AT-MC116XL is 2 kilometers (1.2 miles) when operating at 10 Mbps and 300 meters (984 feet) when operating at 100 Mbps.
If the end-node is capable of half-duplex, the port is set automatically to half-duplex mode. The AT-MC115XL and AT-MC116XL media converters can operate in full- duplex, half-duplex, or auto-negotiate the duplex mode. However, the end- nodes connected to these media converters must operate in the same duplex mode to avoid a duplex mode mismatch, which can result in poor network performance.
For example, if the twisted pair cable to the AT-MC115XL were to fail, the media converter would respond by dropping the link on the fiber optic port. In this way, the AT-MC115XL notifies the end-node connected to the fiber optic port that the connection on the twisted pair port has been lost.
AT-MC115XL and AT-MC116XL Installation Guide Note The MissingLink feature is disabled when you perform a link test with the NML/LNK TST button. Consequently, to ensure that the MissingLink feature is activated on the media converter, always set the button to the NML (IN) position during normal network operations.
Overview Network Topologies The AT-MC115XL and AT-MC116XL media converters can be used in two different topologies: standalone and back-to-back. Both types of topologies are described below. Standalone Topology A standalone topology uses one media converter between the end-nodes. Figure 4 illustrates a standalone topology that uses an AT-MC115XL media converter to connect a workstation and a switch.
AT-MC115XL and AT-MC116XL Installation Guide Back-to-Back Topology In some network configurations you may want to interconnect two media converters in what is referred to as a back-to-back topology. In this topology, the media converters not only extend the distance of your network but also convert the fiber optic cable from twisted pair to fiber optic and back again.
Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance. One AT-MC115XL or AT-MC116XL Ethernet and Fast Ethernet Media Converter Four protective feet (for desktop use only)
Table 4 10Base-FL/100Base-SX Fiber Optic Port Cabling Specifications (Full-duplex) Model Fiber Optic Cable Maximum Maximum Allowable Loss Operating Budget Distance AT-MC115XL 50/125 or 62.5/125 300 m (984 ft) 1.5 dB at 850 nm micron multimode AT-MC116XL 2 km (1.2 mi) 1. Operating at 100 Mbps.
AT-MC115XL and AT-MC116XL Installation Guide Reviewing Safety Guidelines Please review the following safety guidelines before installing the media converter. Warning This is a “Class 1 LED product”. Warning Electrical Shock Hazard: To prevent electrical shock, do not remove the cover. There are no user-serviceable parts inside. The unit contains hazardous voltages and should only be opened by a trained and qualified technician.
Installing the Media Converter Installing the Media Converter To install an AT-MC115XL or AT-MC116XL media converter, perform the following procedure: Remove all equipment from the package and store the packaging material in a safe place. Note Do not remove the dust cover from the fiber optic port until you are ready to connect the fiber optic cable.
Page 25
AT-MC115XL and AT-MC116XL Installation Guide Plug the AC/DC power adapter into an appropriate AC power outlet and insert the power plug into the DC receptacle located on the back of the unit. Refer to Figure 7. This step does not apply if you installed the unit in an AT-MCR12 chassis.
Installing the Media Converter Warranty Registration When you finish installing the product, you should register your product by completing the enclosed warranty card and sending it in.
Chapter 3 Troubleshooting Follow the guidelines below to test and troubleshoot the installation in the event of a problem occurs. If the PWR LED is OFF, do the following; If the unit is installed on a desktop, check to be sure that the power adapter is securely connected to a power outlet and that the power adapter cable is securely connected to the back of the media converter.
Page 28
Troubleshooting If the LNK 10 or 100 LED for the fiber optic port is OFF, do the following: Verify that the end-node connected to the port is ON and is operating properly. Check that the fiber optic cable is securely connected to the fiber optic port on the media converter and on the end-node.
Appendix A Technical Specifications Physical Dimensions: W x D x H 10.5 cm x 9.5 cm x 2.5 cm (4.125 in x 3.75 in x 1.0 in) Weight: 294 g (10.4 oz) Environmental Maximum Operating: 0° C to 40° C (32° F to 104° F) Maximum Storage: C to 80 C (-4°...
Table 5 through Table 8 lists the specifications for the 10Base-FL/100Base-SX fiber optic port. Table 5 Fiber Optic Transmitter Model Fiber Fiber Optical Launch Power (dBm) Type Optic Wavelength Diameter Maximum Average Minimum AT-MC115XL 50/125 850 nm -13.0 -15.8 -18.8 microns AT-MC116XL 62.5/125 850 nm -10.0 -12.0 -15.0 microns 1.
Page 31
AT-MC115XL and AT-MC116XL Installation Guide Table 7 Fiber Optic Datalink Model Fiber Fiber Optical Minimum Average Maximum Type Optic Wavelength Power/ Signal Distance Diameter Link Loss Spec Budget AT-MC115XL 50/125 850 nm 26.40 dB 31.50 dB 300 m microns (984 ft)
Technical Specifications Pinout Assignments Figure 8 shows the pin assignments of the RJ-45 connector. Pin 1 Pin 8 Figure 8 RJ-45 Pin Assignments Table 9 lists the 10Base-T/100Base-TX connector pins and their signals when the port is operating in either MDI or MDI-X configuration. Table 9 RJ-45 Pin Signals MDI-X (Default) Signal...
Appendix B Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
Page 34
Ethernet and Fast Ethernet Media Converters Model Numbers: AT-MC115XL, AT-MC116XL This product complies with FCC Part 15B, Class B Limits: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 35
AT-MC115XL and AT-MC116XL Installation Guide RFI Emission EN55022 Class B Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Immunity EN55024 Warning: This product requires shielded cables to comply with emission and immunity standards.
Page 36
Translated Safety and Emission Information Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. Hochfrequenzstörung EN55022 Klasse B Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen. Störsicherheit EN55024 Achtung: Für dieses Produkt sind abgeschirmte Kabel erforderlich, damit den Richtlinien für Emission und Interferenzschutz entsprochen wird.
Page 37
AT-MC115XL and AT-MC116XL Installation Guide Standarder: Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission EN55022 Klasse B Advarsel: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. Immunitet EN55024 Advarsel: Dette produkt skal bruges med afskærmede kabler for at...
Page 38
Translated Safety and Emission Information Eisen: Dit product voldoet aan de volgende eisen. RFI Emissie EN55022 Klasse B Waarschuwing: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. Immuniteit EN55024 Waarschuwing: Om te voldoen aan de emissie- en immuniteitsnormen dient dit apparaat te zijn voorzien van afgeschermde kabels.
Page 39
AT-MC115XL and AT-MC116XL Installation Guide Normes: ce produit est conforme aux normes de suivantes: Emission d'interférences radioélectriques EN55022 Classe B Mise En Garde: dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
Page 40
Translated Safety and Emission Information Standardit: Tämä tuote on seuraavien standardien mukainen. Radioaaltojen häirintä EN55022 Luokka B Varoitus: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. Kestävyys EN55024 Varoitus: Tämä tuote vaatii suojattuja kaapeleita toimiakseen emissio- ja häiriönsietostandardien mukaisesti.
Page 41
AT-MC115XL and AT-MC116XL Installation Guide Standard: Questo prodotto è conforme ai seguenti standard. Emissione RFI (interferenza di radiofrequenza) EN55022 Classe B Avvertenza: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
Page 42
Translated Safety and Emission Information Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. RFI stråling EN55022 Klasse B Advarsel: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. Immunitet EN55024 Advarsel: Dette produktet må brukes med vernede kabler for å tilfredsstille emisjons- og fritakelsesstandarder.
Page 43
AT-MC115XL and AT-MC116XL Installation Guide Padrões: Este produto atende aos seguintes padrões. Emissão De Interferência De Radiofrequência EN55022 Classe B Aviso: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Page 44
Translated Safety and Emission Information Estándares Este producto cumple con los siguientes estándares. Emisión RFI EN55022 Clase B Advertencia: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto. Inmunidad EN55024 Advertencia: Este producto exige cables protectores para ajustarse a las...
Page 45
AT-MC115XL and AT-MC116XL Installation Guide Standarder: Denna produkt uppfyller följande standarder. Radiostörning EN55022 Klass B Varning: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. Immunitet EN55024 Varning! Denna produkt kräver skärmade kablar för att uppfylla standardkraven för emission och immunitet.
Need help?
Do you have a question about the AT-MC115XL and is the answer not in the manual?
Questions and answers