Japan Radio Co. WIPAS2 Instruction Manual page 41

Point to point
Table of Contents

Advertisement

Contents
Interface
Cable length
Connector shape
Pin assign
Cable type
Range of applicable
outer
Contents
Applicable Cable
Applicable terminal
Note
Contents
・ When closing the Small lid, make sure that the rubber packing of the Small lid is free from
any foreign matter.
(1) Ethernet Connector
Connect the user network via. PoE PSE
1000BASE-T, 100BASE-TX, 10BASE-T
Maximum 100m.
In case of PoE HUB use:100m is from the WT to PoE HUB
In case of PoE injector use: 100m is from the WT via PoE injector to
HUB. (Because, there is no function of terminate PHY in the PoE
injector)
RJ-45
- ETHER signal: MDI-X
- POWER: IEEE802.3at Type2
Ethernet cable for outdoor,
diameter φ4.0 mm - 7.0mm
(2) FG Terminal
Connect the ground wire.
Ground wire 1.6□ (AWG#14)
FG terminal M6 nut.
ground resistance is 100 Ω or less
(3)
Voltage Monitor Terminal For Receiving Level
It is a terminal monitoring a receiving level by using voltage circuit
tester.
STP(Shield Twisted
3-23
Pair)