User Program - Orton AutoFire Plus User Manual

Autofire series kiln controller
Table of Contents

Advertisement

AutoFire® Kiln Controller

USER Program -

using your controller for custom firing programs.
The Up Arrow
The Right Arrow
The AutoFire® family of kiln controllers feature 10 segment user programs for custom firing profiles.
Just follow these simple steps:
Step
Press
1
USER PROGRAM
2
UP/RIGHT ARROWS Scroll to the desired User Program.
3
ENTER
4
RIGHT ARROW
5
UP ARROW
6
-
7
ENTER
8
RIGHT ARROW
9
UP ARROW
10
-
11
ENTER
12
RIGHT ARROW
13
UP ARROW
14
-
15
ENTER
16
17
STOP/START
18
STOP/START
19
STOP/START
increments the value 0 – 9, or scrolls through selections one at a time.
shifts editing digit to the right, or scrolls through selections one at a time.
(controller temperature is displayed in °F)
Description
Enters the User Program mode. Allows the entering
of a 'New ' program, or editing of an existing one.
Selects the desired User Program.
Displays the first program segment name, Ramp 1
Selects the digit to be modified. The selected
digit will flash.
Scroll the selected digit to the desired value.
Repeat steps 4 & 5 till desired value is displayed
Stores the new value and displays the next program
segment name, Dwell Temperature (°F 1 or °C 1)
Selects the digit to be modified. The selected digit flashes
Scroll the selected digit to the desired value.
Repeat steps 8 & 9 till desired value is displayed
Stores the new value and displays the third program
segment name, Dwell Time 1 (Hd 1).
Selects the digit to be modified. The selected digit
will flash.
Scroll the selected digit to the desired value.
Repeat steps 11 & 12 till desired value is displayed
Stores new value and displays the next program ramp
segment. Skip to Step #17 if no more ramps are desired.
Repeat Steps 4-14 for each ramp, dwell temperature, and dwell time desired.
Acknowledges completion of the completed program
and stores the current program into memory.
Starts the current user program just entered
Aborts firing cycle, if necessary during firing
User's Guide
Display
Usr # (where # is a
value of 1, 2, 3, or 4)
USr1, 2, 3, or 4
rA 1, xxxx - where
xxxx is the ramp rate
xxxx
0xxx
0360- ramp of 360°/hr
°F 1 , xxxx - where
xxxx is dwell Temp.
xxxx
1xxx
1032 - dwell temp.
of 1032°F
Hd 1, 0.000
0.000
0.120 (2 hour hold)
rA 2, 0000
IdLE
xxxx – (current
kiln temperature)
Abrt
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autofire proAutofire unitemp

Table of Contents