AutoFire® Kiln Controller
FAn - Vent Fan Operation
The FAn feature is enabled by the factory, and is only available when the controller has been pre-wired to
permit a kiln vent to be turned on or off as part of the firing cycle. There are five modes of operation:
Off
– fan is always off during firing
On
– fan is always on during the firing
OptA – fan is on at 100
fan on at 1000
OptB – fan on when 100
off when 300
th
Fn #
– 4
segment of a USER program where vent fan is set for on or off
For more information on how to program and use the vent fan feature, see Appendix D
dIFF - Temperature Differential
(UniTemp™ Model Only)
The dIFF feature enables the user to display the temperature difference between the top thermocouple and the
bottom thermocouple used with AutoFire® UniTemp™ Models.
temperature uniformity within a kiln during a firing.
rEtn - Return
The rEtn (Return) feature is used to exit the options mode and return to the IdLE or run display.
F and off at 1450
F during heating
O
O
F and off at 300
F during cooling
O
O
O
F reached during heating and
F reached during cooling
O
User's Guide