Display Reference

The following is a reference guide to the various messages that may be displayed while using your AutoFire®
Kiln Controller:
Display
Meaning
0--1
Display Temperatures of both thermocouples (UniTemp™ Models Only)
Abrt
Active Firing Cycle Aborted
AInG
Factory Use Only
ALAr
Kiln Temperature Threshold Alarm (user adjustable)
bAdP
Invalid step in User Program
Change Temperature Units, °F or °C
CHG-
CPLt
Firing Cycle Complete (final temperature reached will alternately be displayed)
CtbL
Cone Table - list of Cone Numbers and their bending temperatures (see Appendix B)
d.ELA
Delay mode (will alternately display the remaining minutes before start of firing)
°F #
Dwell Temperature °F (#: 1-10) - set temperature for controller to ramp to
°C #
Dwell Temperature °C (#: 1-10) - set temperature for controller to ramp to
dIFF
Temperature Difference between two thermocouples (UniTemp™ Models Only)
ELEC
Display Electronics Temperature
Fail
Thermocouple failure
'Fn #'
Vent Fan mode of operation
Hd #
Soak Time in minutes (#: 1-10) – set time for controller to hold temperature
HI F
Hi Fire (display used when reviewing program during a cone firing)
Id
Specify RS-485 Controller Identification Node (number)
IdLE
Controller in Idle mode (ready to program or to start a firing)
Lo
Program Lock 'On' (Cone Fire and User Program cannot be modified)
Lo F
Lo Fire (display used when reviewing program during a cone firing)
LoUn
Program Lock Mode (use to secure program settings from being changed)
≡IdF
Mid Fire (display used when reviewing program during a cone firing )
≡odl
Display Model Number (i.e. 0000 = Plus, 0003 = UniTemp™)
nnnn
Factory Use Only
oFSt
Cone Offset, allows for adjusting display temperature to match witness cones
P1
Bad Firing, thermocouple opened just prior to loosing power
P2
Temperature Invalid Prior To Power Loss (greater then 255°)
P3
Power Loss Too Long (greater then 60 minutes)
ProG
Program Review (use to review active firing program Cone fire or User Program)
rA #
Ramp (#: 1-10) (rate per hour of temperature increase/decrease)
rHEo
Middle Zone Rheostat adjustment (UniTemp™ Models Only)
rEL
Relays 1,2, or 3 (UniTemp™ Models Only)
Ser
Display Serial Number
SoFt
Display Software Version
Firing Speed (Std or ± 40%)
Spd
SStP
Skip Step (used to advance to next ramp)
tCo
Top thermocouple failure (Unitemp)
tC1
Bottom termocouple failure (Unitemp)
tEdE
Temperature Deviation (default 100° corresponding alarm is FtH, FtC, HtdE, LtdE)
rEtn
Return
tC
Select Thermocouple Type K, N, or S
tCnt
Factory Use Only
Un
Program Lock 'Off', all programs and parameters can be modified
Usr#
User Program (#: 1-4)
User's Guide
11