Alarm Reference

The following is a reference guide to the alarm conditions that may be encountered while using your AutoFire®
Kiln Controller (refer to page 20).
Display
Meaning
ALAr
Kiln Threshold Temperature reached threshold temperature alarm set by user
FtH
Fail to Heat - kiln unable to heat at program ramp - temperature is below set-point by deviation
amount*
FtC
Fail to Cool - kiln unable to cool at program ramp - temperature is above set-point by deviation
amount*
HtdE
High Temperature Deviation - kiln above set-point by deviation amount*
LtdE
Low Temperature Deviation - kiln below set-point by deviation amount*
LBAt
Low Battery
tC 0
Top Thermocouple has failed during firing (UniTemp™ Models Only)
tC 1
Bottom Thermocouple has failed during firing (UniTemp™ Models Only)
tCdE
Thermocouple Deviation Alarm - Factory Set for > 60°C (UniTemp™ Models Only)
*temperature deviation alarms occur when the kiln temperature differs from the set-point temperature by the
alarm value. Typically, this is factory set at 100°F (56°C). It is changed through Options (see page 17&18)
Display
Meaning
FtL
Firing Too Long - kiln not increasing in temperature. Temperature increasing at less than 15
C/hr AND the firing time is 4 hours longer than the program segment
O
EtH
Electronics Too Hot – electronics temperature exceeds 85
FAIL
Open Thermocouple – thermocouple(s) has failed (opened)
tC01
Both Thermocouples are 'open' in IdLE mode (UniTemp™ Models Only)
PLOG
Diagnostic tests to determine if controller operating properly
'To reset PLOG error, press 'ENTER', refer to page 22 for additional details.
[Audible Alarm Only]
[Terminating Alarms]