14 • vacon
6.2
Basic parameters (Control keypad: Menu M2
Code
Parameter
P2.1.1
Max frequency
P2.1.2
Acceleration time 1
P2.1.3
Deceleration time 1
P2.1.4
Current limit
Nominal voltage of
P2.1.5
the motor
Nominal frequency
P2.1.6
of the motor
Nominal speed of
P2.1.7
the motor
Nominal current of
P2.1.8
the motor
P2.1.9
Motor cosϕ
P2.1.10
I/O Reference
Keypad control
P2.1.11
reference
Fieldbus control
P2.1.12
reference
Jogging speed
P2.1.13
reference
P2.1.14
Preset speed 1
P2.1.15
Preset speed 2
P2.1.16
Preset speed 3
P2.1.17
Preset speed 4
P2.1.18
Preset speed 5
P2.1.19
Preset speed 6
P2.1.20
Preset speed 7
Table 3. Basic parameters G2.1
6
shaft synchronization application – parameter lists
Min
Max
Unit
Par. 2.1.1
320,00
Hz
0,1
3000,0
s
0,1
3000,0
s
0,4 x I
2 x I
A
H
H
180
690
V
30,00
320,00
Hz
300
20 000
rpm
0,4 x I
2 x I
A
H
H
0,30
1,00
0
14
0
9
0
9
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
0,00
Par. 2.1.2
Hz
G2.1)
Default
Cust
ID
50,00
102
1,0
103
1,0
104
I
107
L
NX2: 230V
NX5: 400V
110
NX6: 690V
50,00
111
1440
112
I
113
H
0,85
120
0
117
8
121
9
122
5,00
124
10,00
105
15,00
106
20,00
126
25,00
127
30,00
128
40,00
129
50,00
130
Tel. +358 (0)201 2121 • Fax +358 (0)201 212 205
Note
NOTE: If f
> than the
max
motor synchronous speed,
check suitability for motor
and drive system
Check the rating plate of
the motor
The default applies for a 4-
pole motor and a nominal
size frequency converter.
Check the rating plate of
the motor.
Check the rating plate of
the motor
0=AI1
1=AI2
2=AI1+AI2
3=AI1-AI2
4=AI2-AI1
5=AI1xAI2
6=AI1 Joystick
7=AI2 Joystick
8=Keypad
9=Fieldbus
10=Motor potentiometer
11=AI1, AI2 minimum
12=AI1, AI2 maximum
13=Max frequency
14=AI1/AI2 selection
0=AI1
1=AI2
2=AI1+AI2
3=AI1-AI2
4=AI2-AI1
5=AI1xAI2
6=AI1 Joystick
7=AI2 Joystick
8=Keypad
9=Fieldbus
See par. 2.1.12
Multi-step speed 1
Multi-step speed 2
Multi-step speed 3
Multi-step speed 4
Multi-step speed 5
Multi-step speed 6
Multi-step speed 7